86
HIM/MIM/MIC/MIC-X failures
Symptom
When a HIM/MIM/MIC/MIC-X is plugged while the router is running, the following information might
appear on the configuration terminal:
%Apr 26 15:36:09:404 2017 H3C DRVICOUT/1/DrvIcOutStr:Slot=5;(Src Slot[5])
Slot 5/2 Plug In Failed!
Solution
To resolve the issue:
1.
Verify that the HIM/MIM/MIC/MIC-X is installed securely.
2.
Verify that the HIM/MIM/MIC/MIC-X is installed correctly in a FIP module. For
HIM/MIM/MIC/MIC-X and FIP module compatibility, see
H3C SR6600/SR6600-X Routers
Interface Module Guide
.
3.
Verify that the interface module connector pins of the FIP module are bent.
4.
If the issue persists, contact H3C Support.
Configuration system issues
If the configuration environment setup is correct, the configuration terminal displays boot information
when the router is powered on. If the setup is incorrect, the configuration terminal displays nothing or
garbled text.
No terminal display
Symptom
The configuration terminal displays nothing when the router is powered on.
Solution
To resolve the issue:
1.
Verify that the power supply system is operating correctly and the console cable is correctly
connected.
2.
Verify that the console cable is connected to a correct serial port.
3.
Verify that the following terminal settings are correct:
{
Bits per second
—9600.
{
Data bits
—8.
{
Parity
—None.
{
Stop bits
—1.
{
Flow control
—None.
{
Terminal emulation
—VT100.
4.
If the issue persists, contact H3C Support.
Garbled terminal display
Symptom
Terminal display is garbled.