25
2.
Loosen the captive screws on the filler panel, and then remove the filler panel.
3.
Use even pressure to gently push the SAP module into the slot along the slide rails until the
positioning pins on the backplane are seated in the positioning holes, and then push the ejector
levers inward to lock the SAP module in position.
Figure 19 Inserting a SAP module
4.
Fasten the captive screws on the SAP module.
5.
Observe the RUN LED on the SAP module to verify that the SAP module is installed correctly.
After the router is powered on, the RUN LED on the SAP flashes green once and then fast
flashes (at 8 Hz) until the application software is loaded. When the RUN LED flashes green at 1
Hz, the SAP is operating correctly.
Installing a HIM/MIM/MIC/MIC-X interface module
CAUTION:
•
MIM interface modules are not hot swappable, but the MIC and MIC-X interface modules are hot
swappable.
•
To hot swap a HIM interface module, you must first execute the
remove slot slotnumber
subslot subslotnumber
command (specifying the HIM interface module to be removed in
the command).
•
To avoid hardware damage, when the RUN LED on a FIP module is fast flashing green, do not
install or remove a HIM/MIM/MIC/MIC-X module on it.