71
4.
Install a new RPE-X1 MPU. For more information, see "
RPE-X1/RPE-X3/RPE-X5/RPE-X5E MPU
."
Replacing an RSE-X1 MPU
1.
Determine the MPU to be removed. This section takes the MPU in slot 5 as an example.
2.
Loosen the captive screws of the MPU to be removed until all spring pressure is released.
3.
Holding the ejector levers of the MPU with both hands, pull the ejector levers outward, and
gently pull the MPU out of the slot along the slide rails.
Figure 72 Pulling the RSE-X1 MPU out of the slot
4.
If you do not install a new MPU in the slot, install a filler panel. To install a new MPU, see
"
Replacing an MCP
To replace an MCP, for example, MCP-X1:
1.
Determine the MCP to be removed. This section takes the MCP in slot 5 as an example.
2.
Loosen the captive screws on the MCP to be removed until all spring pressure is released.
3.
Holding the ejector levers of the MCP with both hands, pull the ejector levers outward, and
gently pull the MCP out of the slot along the slide rails.