93
•
A link is present for the end operating at 10 Mbps, but the physical layer LED (for example, the
Active LED) keeps flashing, and the port cannot transmit or receive traffic correctly.
Solution
To resolve the issue:
1.
Change the rate and duplex mode of a port by force to make sure the rate and duplex mode of
the local end are the same as the peer end.
For the copper FE ports and GE ports, both the rate and duplex mode are auto-negotiated by
default.
2.
If the issue persists, contact H3C Support.
Interface module, cable, and connection failure
Symptom
After a HIM/MIM/MIC/MIC-X is installed and the router is powered on, the LEDs on the
HIM/MIM/MIC/MIC-X panel might indicate abnormal operation.
Solution
To resolve the issue:
1.
Verify that the HIM/MIM/MIC/MIC-X cable is correctly selected.
2.
Verify that the HIM/MIM/MIC/MIC-X cable is correctly connected.
3.
Use the
display
command to identify whether the interface on the interface module has been
correctly configured and is operating correctly.
4.
If the issue persists, contact H3C Support.
Software upgrade failures
No response from the serial port of the MPU
Symptom
The serial port of the MPU gives no response.
Solution
To resolve the issue:
1.
Verify that the serial port settings are correct (whether the
Bits per second
field is set to 9600
kbps).
2.
If the issue persists, contact H3C Support.
For more information about the serial port settings, see "
TFTP upgrade failure
Symptom
Start the router, and upgrade the software through TFTP. The following issues might occur:
•
The CF card has no enough space.
File will be transferred in binary mode
Downloading file from remote TFTP server, please wait...\
Failed to write data into storage device, maybe no enough space on device