118
By default, pressing the power button on a powered-off device starts the Comware system but not
the virtual machines. You can use the
autostart
command to configure the virtual machines to be
started together with the Comware system.
Typically, you can use the
reboot
command to reboot the RPE-X5E MPU. However, if the
RPE-X5E MPU is powered off by pressing the power button, you need to press the power button to
turn it on and then execute the
reboot
command.
RESET button
CAUTION:
•
If you perform no save operation before resetting the router, the current system configuration will
be lost.
•
Never press the RESET button when the RUN LED is flashing fast or when the router is
accessing the CF card or a USB storage device. Otherwise, the file system of the router might be
damaged.
To reset the current MPU, press the RESET button.
•
If you press the RESET button when only one MPU is equipped, the whole system will be reset.
•
To perform an active/standby switchover when two MPUs are equipped, press the RESET
button on the active MPU. The system automatically switches the services to the standby MPU,
without interrupting the ongoing services.
•
If you press the RESET button on the standby MPU when two MPUs are equipped, the standby
MPU will be reset but the system operation will not be affected.
The RUN LED goes off when the MPU is reset, flashes fast (at 8 Hz) when BootWare is running, and
flashes slowly (at 1 Hz) after the system is booted and operates correctly.
Switching fabric modules
The SR6616 router supports switching fabric modules only when it is installed with the
RPE-X3/RPE-X5/RPE-X5E MPU.
SFE-L1
Front panel
Figure 108 SFE-L1 front panel
(1) Captive screw
(2) Ejector lever
(3) Switching fabric module status LED (RUN)