61
…Omitted…
Displaying detailed information about a module
Use the
display device verbose
command to display detailed information of modules in each
slot.
<Sysname>display device verbose
System-mode(Current/After Reboot): Normal/Normal
Slot No. Board type Status Primary SubSlots
---------------------------------------------------------------------
0 N/A Absent N/A N/A
1 N/A Absent N/A N/A
2 N/A Absent N/A N/A
3 N/A Absent N/A N/A
4 RPE-X1 Normal Master 0
5 N/A Absent N/A N/A
6 N/A Absent N/A N/A
7 FIP-210 Startup N/A 2
8 N/A Absent N/A N/A
9 N/A Absent N/A N/A
Use the
display device slot
slot-number
command to display detailed information about
the module in the specified slot.
<Sysname> display device slot 4
System-mode(Current/After Reboot): Normal/Normal
Slot 4 : RPE-X1
SubSlot No. Card Type Status Max Ports
--------------------------------------------------------
0 Fixed SubCard Normal 3
Table 13 Command output
Field Description
Slot No.
Slot number of the module
Card Type
Module model. The value
NONE
indicates that no module is present in the slot.
Status
Running status of the module:
•
Absent
—No module is present in the slot.
•
Fault
—The module in the slot is booting, or the module fails and cannot boot
correctly.
•
Normal
—The module in the slot is a service module and is operating correctly.
Max Ports
Maximum number of submodules that that module supports.
Displaying the electrical label information for a module
Use the
display device manuinfo
command to display the electrical label information of the
module in each slot.
Electrical label information is also called permanent configuration data or archive information, which
includes the module name, serial number, MAC address, and vendor name.
<Sysname> display device manuinfo