The system displays the following information when it cannot provide enough power.
%Apr 26 12:07:42:320 2017 H3C DRVMSG/1/InSufficientPwr:
No sufficient power, failed to power on slot 3.
{
The system displays the following information when a redundant power supply fails.
%Apr 26 16:16:49:518 2017 H3C DRVMSG/1/REDUNDANT POWER-SUPPLY FAILURE:
Redundant power-supply failed, left 0 unit(s).
2.
Resolve the issue based on the output.
3.
If the issue persists, contact H3C support.
FIP module failures
RUN LED is off
Symptom
The RUN LED on the FIP module is off.
Solution
To resolve the issue:
1.
Verify that the router is powered on.
2.
Verify that the FIP module is installed in a right slot.
3.
Verify that the system provides enough power. If the power is not enough, the system displays
the following information:
%Apr 26 16:46:32:169 2017 H3C DRVMSG/1/InSufficientPwr:
No sufficient power, failed to power on slot 3.
4.
If the issue persists, contact H3C Support..
RUN LED fast flashes
Symptom
20 minutes after the router is powered on or the FIP module is installed in the router, the RUN LED
on the FIP module still fast flashes at 8 Hz.
Solution
To resolve the issue, contact H3C Support.
Power module failures
Power LED is off
Symptom
The router cannot be powered on and the power LED on the front panel is off.
Solution
To resolve the issue:
1.
Verify that the power switch is turned on.
2.
Verify that the power cables of the router are firmly connected.
3.
Verify that the switch of the power source is turned on.