162
LED
Status
Description
(green)
RUN
Off
No power input is available or the FIP has failed.
Slow flashing (1
Hz)
The FIP is operating correctly.
Fast flashing (8
Hz)
System software is being loaded. To avoid damage to
the FIP, never power off the device or hot-swap the
FIP.
(yellow/green)
SFP+
Off
No link is present.
Steady green
A 10 Gbps link is present.
Flashing green
Data is being received or transmitted at 10 Gbps.
Steady yellow
POST has failed.
Figure 147 FIP-380 LEDs
Table 85 FIP-380 LED description
LED Status
Description
(yellow/green)
SFP+22 and
SFP+23
Off
No link is present on the port or the port is faulty.
Steady yellow
A 1000 Mbps link is present on the port.
Flashing yellow (8 Hz)
The port is sending and receiving data at 1000
Mbps.
Steady green
A 10 Gbps link is present on the port.
Flashing green (8 Hz)
The port is sending and receiving data at 10
Gbps.
(yellow/green)
SFP0 to
SFP13
Off
No link is present on the port or the port is faulty.
Steady yellow
A 100 Mbps link is present on the port.
Flashing yellow (8 Hz)
The port is sending and receiving data at 100
Mbps.
Steady green
A 1000 Mbps link is present on the port.
Flashing green (8 Hz)
The port is sending and receiving data at 1000
Mbps.
(green)
RUN
Off
No power is being input or the FIP has failed.
Steady green
The FIP software system is starting up.
Flashing green (1 Hz)
The FIP is operating correctly.
Flashing green (8 Hz)
The FIP is loading software.
3
4
3
2
4
1