66
Configuring a combo interface
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter view of the SFP port
or RJ-45 port of the combo
interface.
interface
interface-type
interface-number
N/A
3.
Activate the RJ-45 Ethernet
port or SFP port.
combo enable
{
copper
|
fiber
}
Required.
By default, the Ethernet port is active.
Displaying transceiver module information and alarming
information
Introduction to transceiver modules
Table 20 Commonly used transceiver modules
Transceiver module
type
Application scenarios
Whether can
be an optical
transceiver
Whether can be
an electrical
transceiver
SFP (Small Form-factor
Pluggable)
Generally used for 100M/1000M
Ethernet interfaces or POS
155M/622M/2.5G interfaces
Yes Yes
XFP(10-Gigabit small
Form-factor Pluggable)
Generally used for 10G interfaces
Yes
No
SFP+
Generally used for 10G interfaces
Yes
No
Displaying transceiver module information
To identify transceiver modules, you can use the following command to view the key parameters of
the transceiver modules, including transceiver module type, connector type, central wavelength of
the laser sent, transmission distance, and vendor name or name of the vendor who customizes the
transceiver modules.
To display transceiver module information:
Task Command
Remarks
Display key parameters of the
transceiver module in a specified
interface.
display transceiver
interface
[
interface-type
interface-number
]
Available for all transceiver
modules
Displaying the alarming information or fault detection parameters for a transceiver module
The system outputs alarm information for you to locate and troubleshoot faults of transceiver
modules. For the H3C-customized transceiver modules, the system can also monitor the key
parameters, such as temperature, voltage, laser bias current, TX power, and RX power. When these
parameters are abnormal, you can take corresponding measures to prevent transceiver module
faults.
Perform the following operation to display the alarming information or fault detection parameters of a
transceiver module: