Reverse osmosis system
GENO-OSMO RO 125K
Order no.
285 752 940-inter Edited by: phar-mrie G:\BA-752940-INTER_285_RO_125K.DOCX
15
Table C-1: Technical data
Reverse osmosis system GENO-OSMO RO
125K-TS
125K-TL
Connection data
Nominal connection diameter of feed water pipe
½" (DN 15) male thread
Nominal connection diameter of permeate outlet
½" (DN 15) male thread
Nominal connection diameter of concentrate
outlet
½" (DN 15) male thread
Min. drain connection required
DN 50
Connected load, approx.
[kW]
0.85
0.50
Power supply
[V/Hz]
230/50
Protection/protection class
IP 54/
Performance data
Permeate output at a feed water temperature of
10 °C/15 °C
[l/h]
105/125
Electrical capacity of pump at operating
pressure
[kW]
0.37
Permeate output per day (max. 24 h) approx.
min./max.
[m³/d]
2.5/3.0
Inlet flow pressure of feed water, min.
[bar]
2.5
Permeate supply approx.
[l]
38
-
Pump characteristic curve pressure booster
[l/h/bar]
300/3.5 – 1200/1.0
-
Nominal pressure
PN 16
Salt rejection
95 – 99 %
Total salt concentration of the feed water as NaCl,
max.
[ppm]
1000
Concentrate volume flow, min./max. (at 15 °C)
[l/h]
40/125
Feed water volume flow
(fresh water 15 °C) at a recovery of 75 %, max.
[l/h]
160
Recovery min./max.
[%]
50 – 75 (adjustable)
Dimensions and weights
Dimensions (w x d x h)
[mm]
450 x 600 x 1130
Empty weight, approx.
[kg]
37
30
Operating weight, approx.
[kg]
75
30
Ambient data
Feed water temperature min./max.
[°C]
10/30
1)
Ambient temperature, min./max.
[°C]
5/35
Order no.
752 100
752 110
1)
For feed water temperatures > 20 °C, a separate design of the system is required.