3 | Intended use
The reverse osmosis system GENO-OSMO RO 125K is used for
the demineralisation of feed waters. The water is primarily used for
industrial applications.
The system can be used only after a prior water analysis and
corresponding pretreatment.
The permeate capacity of the system depends on the temperature
and is defined at 15 °C. The permeate outputs can fall (falling
temperature) or rise (rising temperature) by up to 3 % for each °C rise
or fall in the feed water temperature.
The system is adjusted to the permeate requirements to be expected
at the installation site, it is not suitable for major deviations.
Only operate the system if all components are properly installed.
Safety devices and equipment must NEVER be removed, bridged or
tampered with.
Intended use of the device also implies that the information contained
in this operation manual and all safety guidelines applying at the
installation site be observed. Furthermore, the maintenance and
inspection intervals must be respected.
3.1 | System shut-down
If the system is shut down for more than 14 days, the reverse
osmosis system must be preserved by Grünbeck's technical customer
service/authorised service company. The maximum time, the system
can remain in the preserved condition is 6 months.
In case the down time is longer, the system must be preserved
again in regular intervals by Grünbeck's technical customer
service/authorised service company. Prior to resuming operation,
the preserving agent must be flushed from the system.