Reverse osmosis system
GENO-OSMO RO 125K
Order no.
285 752 940-inter Edited by: phar-mrie G:\BA-752940-INTER_285_RO_125K.DOCX
17
4 | Application limits
For the application of the reverse osmosis system GENO-OSMO
RO 125K, the limit values stipulated in the German Drinking Water
Ordinance represent the upper limits for the admissible substances
contained in the water.
Total hardness < 0.1°dH (0.178°f, 0.0178 mmol/l)
Free chlorine not detectable
Iron < 0.1 mg/l
Manganese < 0.05 mg/l
Silicate < 15 mg/l
Chlorine dioxide not detectable
Turbidity < 1 FTU
Colloid index < 3
pH range 3 - 9
Note
: The permeate originating from the reverse osmosis system is
not potable but requires additional treatment (blending, hardening) if it
is to be used as drinking water.