NP30A or NP40A
Applicator Operating Instructions
77
2019-03-11
407-502M
Stopping Application
Plan your stops. A safe stop requires depleting the
anhydrous, from the nurse tank withdrawal valve to the
knives or tines.
a. What is the wind direction?
b. Suspend application per “
c. Put on your chemical gloves.
Be wearing your goggles.
d. Carefully approach the nurse tank from up-wind.
Expect some ammonia odor, but if it is extremely
strong, there may be an above-ground release in
progress due to malfunction or part failure. If so,
remain clear until the release subsides.
e. When safe to do so, shut off the nurse tank
withdrawal valve
.
f.
Re-enter the tractor cab.
g. Turn MASTER switch ON.
h. Resume field application until reported rate begins to
fall. Increase rate to maximum (to fully open Control
Valve
).
i.
Continue field application until both cooler and
divider pressure gauges read zero.
j.
Facing into the wind, raise the applicator and stop.
k. Set the MASTER switch to OFF.
l.
Wait at least 1 minute for row line vapor to dissipate.
m. Turn so that the wind is directly from the right.
n. Open all bleed valves. Standing up-wind of each,
and making sure orifices point away from you, slowly
open bleed valves at:
• nurse tank hose inlet end
• nurse tank hose outlet end
• breakaway valve (
or
, whichever is safer)
• cooler temperature gauge
.
o. Close all remaining operating valves:
• nurse tank hose inlet end
• nurse tank hose outlet end
• emergency shut-off valve
.
p. Wait at least one hour before moving applicator to
any spot near unprotected people or livestock. It will
continue to out-gas ammonia vapor for some time.
Ball Valves: Trapped NH
3
Hazard:
Avoid routinely closing ball valves (other than the nurse tank
withdrawal valve) with liquid NH
3
in the lines. Fluid is
trapped in the line above the valve, may trigger relief valves,
and can get trapped inside the valve ball unless it has a bleed
port (not yet common on nurse tank hoses).
A typical ball valve can trap enough NH
3
to make a room the
size of a two-care garage uninhabitable (concentrations above
IDLH in moments). When the ball valve is later opened, while
warm, the NH
3
is expelled at high pressure. If the line is
pointed at your face, you could receive a fatal exposure.