2019-03-11
407-502M
NP30A or NP40A
Adjustments
94
Field Fold Stop Adjustment
This applies to 2103+ 5-Section applicators only.
During field fold (FOLD / FIELD switch in FIELD), the
inner wing sections are intended to stop 5 to 10°
above wings-level relative to the center section
. The
stopping point is controlled by an angled proximity
sensor
at each center/wing hinge. If a wing does not
stop in this range, adjust the proximity sensor.
1. Verify that the misalignment is not caused by air in
the hydraulic system. Do not use the proximity
adjustment to compensate for hydraulic problems.
2. Move the applicator to a level surface. Raise and fold
(page 62). Install lift-assist lock channels (page 45)
and parking stands (page 36).
3. Set the FOLD / FIELD switch to FOLD. Extend the
fold/lift circuit to unfold until the inner wings stop.
4. Set the FOLD / FIELD switch to FIELD. Retract the
fold/lift circuit until the wings stop at “gull wing” (field
lift, page 56). Set the circuit to Neutral. Shut off the
tractor.
5. Check the sensor-actuator (
-
) gap at the
affected wing pivot. With the actuator near the
marked region on the sensor, the gap must be:
1
/
8
to
1
/
4
inch (3.2 to 6.3 mm)
If the gap is incorrect, correct that, at the current
sensor height. Fold and unfold to see if further
adjustment is required.
6. To adjust the sensor, loosen the bolts securing the
sensor
to the bracket. Do not adjust the
actuator
position.
To lower the angle at which the wing stops, raise the
sensor.
To raise the angle at which the wing stops, lower the
sensor.
7. Secure the bolts. Fold and unfold to test.
-
+
Figure 71
Field Fold Stop Proximity Sensor
34992