4. Work through the wizard as follows:
a) At each wizard page, read messages in the center window to follow progress and wait until
the green indicator verifies that operations are complete. Then click
Next
to proceed.
b) When prompted, browse to and select the folder that contains the controller microcode.
c) When waiting for the controller to reboot, proceed after a "Controller...back online" message
is displayed in the center window.
d) If the RAID controller chassis has redundant controllers, after working through pages for
Controller 1, work through similar pages for Controller 2.
You do not need to select microcode for Controller 2. The microcode you selected for
Controller 1 is automatically loaded onto Controller 2.
5. On completion, proceed as follows:
•
If the RAID controller chassis has redundant controllers, power cycle the RAID controller
chassis, then restart the K2 Media Server.
•
If the RAID controller chassis does not have redundant controllers, no power cycle is required.
The firmware download is complete.
Downloading disk drive firmware
Prerequisites are as follows:
•
All K2 clients and other clients must be powered down, or in some other way disconnected from
the K2 SAN.
•
The K2 Media Server through which Storage Utility is connected to the RAID Storage must be
powered up.
•
All other K2 Media Servers must be powered down.
You might be instructed in K2 Release Notes to upgrade disk drive firmware. This allows you to
take advantage of the disk drive enhancements and benefit from improved performance and reliability.
To determine your disk drive type and current firmware version, select a disk drive icon in the
Storage Utility tree view, then note the drive properties reported in the right-hand pane. Use the
following procedure if you need to download disk drive firmware.
NOTE: The disk drives on each controller are upgraded one at a time which can take as long as
2 minutes per drive. Take this into consideration when scheduling the upgrade.
1. Refer to
K2 Release Notes
to determine firmware types, versions, files, and any other special
instructions regarding the particular disk drive firmware you are downloading.
2. In the Storage Utility, right-click a controller in the tree view, then select
Advanced | Download
Disk Firmware
in the context menu.
The Open File dialog box opens.
CAUTION: Do not attempt to download firmware to a single disk, unless directed to do
so by Grass Valley. Downloading to a single disk can trigger a disk rebuild, with potential
loss of data.
318
K2 SAN Installation and Service Manual
2014 01 27
Administering and maintaining the K2 SAN
Содержание K2 SAN
Страница 2: ......
Страница 4: ......
Страница 28: ...28 K2 SAN Installation and Service Manual 2014 01 27 Preface ...
Страница 100: ...100 K2 SAN Installation and Service Manual 2014 01 27 Planning and implementing a K2 SAN with SiteConfig ...
Страница 233: ...2 Shut down the SAN client 2014 01 27 K2 SAN Installation and Service Manual 233 Configuring clients on the K2 SAN ...
Страница 234: ...234 K2 SAN Installation and Service Manual 2014 01 27 Configuring clients on the K2 SAN ...
Страница 237: ...Basic K2 SAN power on procedure 2014 01 27 K2 SAN Installation and Service Manual 237 Operating the K2 SAN ...
Страница 238: ...Redundant K2 SAN power on procedure 238 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 239: ...2014 01 27 K2 SAN Installation and Service Manual 239 Operating the K2 SAN ...
Страница 240: ...Nearline K2 SAN power on procedure 240 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 248: ...248 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 324: ...324 K2 SAN Installation and Service Manual 2014 01 27 Administering and maintaining the K2 SAN ...
Страница 346: ...346 K2 SAN Installation and Service Manual 2014 01 27 Index ...