16. On the Partition or Disk to Restore page, select
(D:)
and then click
Next
.
17. On the Restored Partition Location page, select
(D:)
and then click
Next
.
opens.
18. On the Restored Partition Type page, leave the selection at
Primary
and then click
Next
.
19. On the Restored Partition Size page, leave settings at their defaults. The size reported in the upper
pane is the size detected of the actual D: partition. This should be the same as that reported in
the Partition size field in the middle of the page. Free space before and Free space after should
both be reported at 0 bytes. Click
Next
.
20. On the Next Selection page, select
No, I do not
and then click
Next
.
21. On the Restoration Options page, do not make any selections. Click
Next
.
22. On the “…ready to proceed…” page, verify that you are restoring the correct image to the correct
location. Click
Proceed
.
23. On the Operation Progress page, observe the progress report.
24. When a message appears indicating a successful recovery, click
OK
.
25. Click
Operations | Exit
to exit the Acronis True Image program.
The machine restarts automatically.
26. Remove the recovery media while the machine is shutting down.
27. When prompted, enter the machine name.
Make sure the name is identical to the name it previously had.
At first start up after reimage, the system is in Embedded Security Update mode by default.
Next, do the following to restore the K2 Media Server to its factory-default state. Refer to related
topics in this document or as otherwise indicated.
1. Set up Windows.
2. Restore network configuration.
3. Install the SiteConfig Discovery Agent.
4. Install SNFS software manually. Do not use SiteConfig.
5. Restart.
6. Install K2 software manually. Do not use SiteConfig.
While manually installing software, accept any hardware installation or driver/security prompts
that appear. Also refer to related topics in "K2 Release Notes".
7. Install Fibre Channel Card driver.
8. Activate Windows within 30 days.
Related Topics
Embedded Security modes and policies
on page 116
on page 115
Restoring network configuration
on page 282
Installing the Discovery Agent on a K2 Media Server
on page 114
Installing the Fibre Channel card driver
on page 288
Activating the Windows operating system
on page 116
2014 01 27
K2 SAN Installation and Service Manual
109
Managing K2 Software
Содержание K2 SAN
Страница 2: ......
Страница 4: ......
Страница 28: ...28 K2 SAN Installation and Service Manual 2014 01 27 Preface ...
Страница 100: ...100 K2 SAN Installation and Service Manual 2014 01 27 Planning and implementing a K2 SAN with SiteConfig ...
Страница 233: ...2 Shut down the SAN client 2014 01 27 K2 SAN Installation and Service Manual 233 Configuring clients on the K2 SAN ...
Страница 234: ...234 K2 SAN Installation and Service Manual 2014 01 27 Configuring clients on the K2 SAN ...
Страница 237: ...Basic K2 SAN power on procedure 2014 01 27 K2 SAN Installation and Service Manual 237 Operating the K2 SAN ...
Страница 238: ...Redundant K2 SAN power on procedure 238 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 239: ...2014 01 27 K2 SAN Installation and Service Manual 239 Operating the K2 SAN ...
Страница 240: ...Nearline K2 SAN power on procedure 240 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 248: ...248 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 324: ...324 K2 SAN Installation and Service Manual 2014 01 27 Administering and maintaining the K2 SAN ...
Страница 346: ...346 K2 SAN Installation and Service Manual 2014 01 27 Index ...