2. Right-click one of the adapters and select
Properties
.
The Properties dialog box opens.
3. Click
Configure
.
4. On the
Power Management
tab, uncheck all checkboxes, if they are not already unchecked.
5. Click
OK
.
6. If a “…lose connectivity…” message opens, click
Yes
.
7. Repeat these steps on the remaining network connection in the Network Connections window.
Configure static IP address on Server 2008
This task required on systems with Microsoft Windows Server 2008 operating system only.
SiteConfig cannot discover systems with the Microsoft Windows Server 2008 operating system that
have no IP address, such as those that are configured for DHCP. Therefore you must configure the
system with a static IP address. You can use any IP address.
Removing a K2 Media Server
In a functioning K2 SAN, you should not permanently remove a K2 Media Server that takes the
role of media file system/metadata server, as this changes system capabilities and results in the
failure of some or all of the media operations for which the system was designed. Remove a K2
Media Server only under the direct supervision of qualified Grass Valley personnel.
If you are replacing a faulty server with a replacement server, follow the documented procedure.
Replacing a K2 Media Server
The requirements for replacing a K2 Media Server on an existing K2 SAN are as follows:
•
You must be logged in to the K2Config application with permissions equivalent to K2
administrator or higher.
Use this procedure if a K2 Media Server in a working system is faulty or otherwise needs to be
replaced with a new K2 Media Server.
NOTE: If you are replacing a non-redundant media file system/metadata server, you lose all
media during the replacement process.
1. If the server hosts an iSCSI interface adapter, copy down iSCSI bandwidth settings for K2 clients
and other iSCSI clients that use the faulty server as their iSCSI target, as follows:
a) In the K2Config application, select the K2 SAN in the tree view and then click the button in
the toolbar to view client iSCSI assignments. A page opens that displays each client’s primary
and secondary iSCSI targets.
b) In the tree view, select one of the clients that have the faulty server as a primary or secondary
iSCSI target.
c) Open the client’s iSCSI Initiator Configuration page and click
Modify
. The Bandwidth Input
dialog box opens.
d) Copy down the bandwidth settings configured for that client and then close the Bandwidth
Input dialog box.
e) Repeat these steps for each client that has the faulty server as a primary or secondary iSCSI
target.
2014 01 27
K2 SAN Installation and Service Manual
285
Administering and maintaining the K2 SAN
Содержание K2 SAN
Страница 2: ......
Страница 4: ......
Страница 28: ...28 K2 SAN Installation and Service Manual 2014 01 27 Preface ...
Страница 100: ...100 K2 SAN Installation and Service Manual 2014 01 27 Planning and implementing a K2 SAN with SiteConfig ...
Страница 233: ...2 Shut down the SAN client 2014 01 27 K2 SAN Installation and Service Manual 233 Configuring clients on the K2 SAN ...
Страница 234: ...234 K2 SAN Installation and Service Manual 2014 01 27 Configuring clients on the K2 SAN ...
Страница 237: ...Basic K2 SAN power on procedure 2014 01 27 K2 SAN Installation and Service Manual 237 Operating the K2 SAN ...
Страница 238: ...Redundant K2 SAN power on procedure 238 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 239: ...2014 01 27 K2 SAN Installation and Service Manual 239 Operating the K2 SAN ...
Страница 240: ...Nearline K2 SAN power on procedure 240 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 248: ...248 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 324: ...324 K2 SAN Installation and Service Manual 2014 01 27 Administering and maintaining the K2 SAN ...
Страница 346: ...346 K2 SAN Installation and Service Manual 2014 01 27 Index ...