Flashing disk LEDs
Storage Utility’s Identify feature allows you to flash the disk LEDs so that you can physically locate
a specific disk module or group of disk modules that make up a RANK. Always use the disk identify
feature before removing and replacing a failed disk module. Accidentally removing the wrong disk
module can destroy data.
1. Open Storage Utility and in the tree view expand all nodes so that all disks are displayed.
2. Open the bezel on the RAID storage chassis or otherwise make sure you can see disk LEDs.
3. Identify the disks in a RANK or identify a single disk, as follows:
a) In the Storage Utility tree view, right-click a RANK or right-click a single disk, then select
Identify RANK
or
Identify Disk
in the context menu. A message box opens with a message that
informs you that a disk or disks are blinking.
b) The LEDs for the disk or disks display a flashing pattern. Verify the location of the disk or
disks.
Get K2 10Gv2 RAID controller logs
The K2 10Gv2 RAID controller(s) must be connected to the control network and must have IP
address(es) set (using Storage Utility) to support the operations in this topic.
1. In the Storage Utility tree view, select the controller.
2. Click
Actions | Get Controller Logs
.
The Login Information dialog box opens.
3. If necessary, enable fields and enter username, password, or controller IP address, then click
OK
.
The Gather Logs wizard opens.
4. At each wizard page, read messages in the center window to follow progress and wait until the
green indicator verifies that operations are complete. Then click
Next
to proceed.
5. A message informs you of that logs have been successfully gathered.
6. Find the log files on the K2 Media Sever at
C:\logs
.
312
K2 SAN Installation and Service Manual
2014 01 27
Administering and maintaining the K2 SAN
Содержание K2 SAN
Страница 2: ......
Страница 4: ......
Страница 28: ...28 K2 SAN Installation and Service Manual 2014 01 27 Preface ...
Страница 100: ...100 K2 SAN Installation and Service Manual 2014 01 27 Planning and implementing a K2 SAN with SiteConfig ...
Страница 233: ...2 Shut down the SAN client 2014 01 27 K2 SAN Installation and Service Manual 233 Configuring clients on the K2 SAN ...
Страница 234: ...234 K2 SAN Installation and Service Manual 2014 01 27 Configuring clients on the K2 SAN ...
Страница 237: ...Basic K2 SAN power on procedure 2014 01 27 K2 SAN Installation and Service Manual 237 Operating the K2 SAN ...
Страница 238: ...Redundant K2 SAN power on procedure 238 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 239: ...2014 01 27 K2 SAN Installation and Service Manual 239 Operating the K2 SAN ...
Страница 240: ...Nearline K2 SAN power on procedure 240 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 248: ...248 K2 SAN Installation and Service Manual 2014 01 27 Operating the K2 SAN ...
Страница 324: ...324 K2 SAN Installation and Service Manual 2014 01 27 Administering and maintaining the K2 SAN ...
Страница 346: ...346 K2 SAN Installation and Service Manual 2014 01 27 Index ...