Chass is...
Conn ects
to...
With disk numberin g as
.
.
.
s
i
s
s
a
h
C
:
s
w
o
l
l
o
f
Con nects
to...
With disk nu mbering as
follows:
Primary
DP0
(internal
connection)
00
01
02
03
—
—
—
04
05
06
07
08
09
0A
0B
Expansion 2
DP0
10
11
12
13
Expansion 1
DP1
80
81
82
83
14
15
16
17
84
85
86
87
18
19
1A
1B
88
89
8A
8B
Expansion 4
DP0
20
21
22
23
Expansion 3
DP1
90
91
92
93
24
25
26
27
94
95
96
97
28
29
2A
2B
98
99
9A
9B
Expansion 6
DP0
30
31
32
33
Expansion 5
DP1
A0
A1
A2
A3
34
35
36
37
A4
A5
A6
A7
38
39
3A
3B
A8
A9
AA
AB
Expansion 8
DP0
40
41
42
43
Expansion 7
DP1
B0
B1
B2
B3
44
45
46
47
B4
B5
B6
B7
48
49
4A
4B
B8
B9
BA
BB
Expansion 10
DP0
50
51
52
53
Expansion 9
DP1
C0
C1
C2
C3
54
55
56
57
C4
C5
C6
C7
58
59
5A
5B
C8
C9
CA
CB
Flashing disk LEDs
Storage Utility’s Identify feature allows you to flash the disk LEDs so that you can physically locate
a specific disk module or group of disk modules that make up a RANK. Always use the disk identify
feature before removing and replacing a failed disk module. Accidentally removing the wrong disk
module can destroy data.
1. Open Storage Utility and in the tree view expand all nodes so that all disks are displayed.
2. Open the bezel on the RAID storage chassis or otherwise make sure you can see disk LEDs.
3. Identify the disks in a RANK or identify a single disk, as follows:
a) In the Storage Utility tree view, right-click a RANK or right-click a single disk, then select
Identify RANK
or
Identify Disk
in the context menu. A message box opens with a message that
informs you that a disk or disks are blinking.
b) The LEDs for the disk or disks display a flashing pattern. Verify the location of the disk or
disks.
Get controller logs
1. In the Storage Utility tree view, select the controller.
2. Click
Actions | Get Controller Logs
.
3. A message informs you of the location of the logs.
4. Find the log files on the K2 Media Sever at C:\logs.
02 February 2012
K2 SAN Installation and Service Manual
323
Administering and maintaining the K2 SAN
Содержание K2 BASECAMP EXPRESS
Страница 28: ......
Страница 38: ......
Страница 62: ......
Страница 112: ......
Страница 124: ......
Страница 246: ...Basic K2 SAN power on procedure 246 K2 SAN Installation and Service Manual 02 February 2012 Operating the K2 SAN ...
Страница 247: ...Redundant K2 SAN power on procedure 02 February 2012 K2 SAN Installation and Service Manual 247 Operating the K2 SAN ...
Страница 248: ...248 K2 SAN Installation and Service Manual 02 February 2012 Operating the K2 SAN ...
Страница 249: ...Nearline K2 SAN power on procedure 02 February 2012 K2 SAN Installation and Service Manual 249 Operating the K2 SAN ...
Страница 256: ......
Страница 340: ......
Страница 354: ......
Страница 366: ...366 K2 SAN Installation and Service Manual 02 February 2012 Index ...