Physical Matrix Screen Description
Configuring Concerto Slots
Concerto slots must be configured before the Encore System can be used.
The following procedure assumes that you have an existing Router config-
uration or are in the process of creating one.
1.
Ensure that Concerto modules are in appropriate slot locations and are
properly seated.
Note
Concerto modules location guideline: A module must always be in slot 1.
(Module slots are numbered from top to bottom.) Modules of the same type
must be in adjacent slots. Analog and digital audio modules are treated as if
they were the same type of module.
2.
Ensure that the Concerto and Router Controller are powered up.
3.
Ensure that the Sharer and Router Control applications are running.
4.
Launch the Encore OUI if it's not already running.
5.
Log in and open the Router Control application.
6.
Click the
Config.
button on the Main Menu.
7.
Ensure that you've already created a channel, defined at least one
Crosspoint Group, and assigned a System Controller to it.
8.
Click the
Physical Matrix
button on the Main Menu.
9.
When the Physical Matrix Configuration window appears, choose the
Crosspoint Group/System Controller combination you want to
address.
10.
If you are not configuring Digital Video modules, click the
Controller
Attributes
button in the bottom left corner of the Physical Matrix
Configuration window. (Digital Video modules have no attributes.)
a.
When the Attribute Configuration dialog opens, start at the top and
click a board slot, then select the appropriate attribute value for that
board from the list.
b.
Press the
Return
icon after you've selected the appropriate value.
c.
Repeat this step until you've configured each of the populated slots.
11.
When you've configured all of the populated slots, click the
Eject
button
at the top right corner of the Attribute Configuration dialog.
12.
Now click the
Config
. button and in order, click the
Save
,
Commit Changes
,
Re-Sync Comms
, and
Re-Sync Router
buttons to save and broadcast your
changes.
through
for each configured Crosspoint Group.
Содержание Encore
Страница 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Страница 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Страница 14: ...14 Encore Configuration Manual Contents ...
Страница 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Страница 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Страница 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Страница 285: ...Encore Configuration Manual 285 Available Panel Configuration Screens 48B 48 Button UCP Encore Universal Control ...
Страница 344: ...344 Encore Configuration Manual Section 8 Additional OUI Operations Figure 206 Interlevel Routing Window ...
Страница 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Страница 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...
Страница 426: ...426 Encore Configuration Manual Index ...