Encore — Configuration Manual
69
Initial Setup Using Default Database
5.
The control panels should now have illuminated tally buttons, and
panels with displays will probably report VTR1 (which is the name of
the first Source and Destination in the default database).
Your Encore system should now be ready for its initial test.
Test Initial System Functionality
1.
With two control panels operating and the same Destination selected
on both panels, push a new Source button on a panel. The button tally
lamp should change on both panels to reflect the newly selected Source
on the dummy matrix.
2.
Gently pull the Slot 1 SCB on the left out of its slot a few inches so its
indicator lights go off. This disables the Master Panel Server and Router
Control applications, but the Mirrors of those applications running on
the other SCB should automatically take over.
3.
Again, select a new Source buttons on a control panel. The tally lamps
should change the same as before.
4.
Gently reinsert the SCB fully into its slot.
This confirms that all the Encore system components are communicating
and ready for further configuration.
Confirm Master/Mirror Sync Operation
You can check that the Master and Mirror applications are properly in sync
using the Encore OUI.
1.
Launch the Encore OUI by clicking on its icon on the desktop.
Содержание Encore
Страница 1: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Страница 3: ...Encore CONTROL SYSTEM Configuration Manual Software Version 1 8 0 071853104 OCTOBER 2010 ...
Страница 14: ...14 Encore Configuration Manual Contents ...
Страница 36: ...36 Encore Configuration Manual Section 2 Encore Fundamentals ...
Страница 54: ...54 Encore Configuration Manual Section 3 Encore OUI Description ...
Страница 284: ...284 Encore Configuration Manual Section 6 Control Panel Configuration PMB Paging MultiBus XY ...
Страница 285: ...Encore Configuration Manual 285 Available Panel Configuration Screens 48B 48 Button UCP Encore Universal Control ...
Страница 344: ...344 Encore Configuration Manual Section 8 Additional OUI Operations Figure 206 Interlevel Routing Window ...
Страница 382: ...382 Encore Configuration Manual Section 8 Additional OUI Operations ...
Страница 406: ...406 Encore Configuration Manual Section 9 System Manager Reference ...
Страница 426: ...426 Encore Configuration Manual Index ...