CS610-UM-251-9370
8-29
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
8.22 Adjusting the Thickness Sensor and the Elevator Sensors
Adjusting the thickness sensor
(1) Detach the right cover but do not disconnect any cables from the right cover (see Section 8.1).
(2) Remove the two M2L10 binding head screws holding the low position elevator sensor and then detach
the low position elevator sensor.
Low position elevator sensor
M2L10 binding head screw
M2L10 binding head screw
High position elevator sensor
(3) Verify that the POWER LED and READY LED are lit.
(4) Press the ITA button and then verify that the READY LED goes out, and that the ITA LED lights instead.
(5) Place a sheet of copy paper (paper which is thinner than 1 mm) on the front paper sensor and insert it
into the recess. The top cover starts to rise automatically.
(6) When the top cover has risen to the upper limit position, insert the copy paper further so that it can
be seen from the rear of the scanner. (Lowering starts approximately 5 seconds after the test target is
detected by the front and rear paper sensors.)
(7) When the copy paper is inserted into position, the top cover automatically descends to detect the
thickness.
(8) Confi rm the gap between the 4-mm holes in the slider and the side panel.
Low position elevator sensor
4 mm hole
Slider
High position elevator sensor
The gap between the 4-mm holes in the slider and the side panel
To be within 0.2 mm.
Side Panel
Содержание CS610-11eN
Страница 1: ...COLORIMAGESCANNER SERVICE MANUAL CS610 SERIES CS610 UM251 02 9370...
Страница 2: ......
Страница 42: ......
Страница 44: ......
Страница 118: ......
Страница 120: ......
Страница 123: ...CS610 UM 251 9370 13 3 13 PARTS LIST Main Frame 1 7 6 4 Ethernet board Enhanced I F board 8 9 3 5 2...
Страница 128: ...13 PARTS LIST CS610 UM 251 9370 13 8 CIS Unit 6 4 2 11 9 10 12 8 1 3 5 7...
Страница 130: ...13 PARTS LIST CS610 UM 251 9370 13 10 Top Cover 3 5 2 9 6 10 7 4 8 8 10 11 12 12 12 13 14 15 16 1...