CS610-UM-251-9370
8-2
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
8.3 Top Cover Assembly
Detaching the top cover assembly
(1) Detach the right and left side covers (see Sections 8.1 and 8.2).
(2) Verify that the POWER LED and READY LED are lit.
(3) Press the ITA button and then verify that the READY LED goes out, and that the ITA LED lights instead.
(4) Press the FORWARD button to raise the top cover to the upper limit position.
(5) Open the top cover.
(6) Loosen the two M3L6 binding head screws holding the right top cover plate.
M3L6 binding head screw
(7) Disconnect the connector from the top cover assembly as shown below.
Disconnect this connector