CS610-UM-251-9370
10-19
10. ADJUSTMENTS USING THE SOFTWARE
(6) Check the scanning point of the top center area.
Adjust this gap if there is
gap between the target
edge and the scanning start
point.
(7) Zoom in to the top center area using the zoom button.
If the start point of the scanning is within the top center area as shown below, it does not require offset
adjustment.
(8) If the starting point of the scanning is outside of the top center circle, click the Origin box and then input
"0".
0
(9) Click the "Check" button, then click the "Set" button. The following dialog box will appear.
Click the "OK" button.
(10) Take out the CS600/500/IS200 adjustment test chart from the scanner. And then reinsert the
CS600/500/IS200 adjustment test chart to the scanner.
(11) Click the "Scan" button.