CS610-UM-251-9370
10-11
10. ADJUSTMENTS USING THE SOFTWARE
(6) The following dialog box will appear. Click the "Scan" button.
Select the following for "Document Info" and "Scan Settings":
"Document Info"
Paper Size
: User Size, Width: 1066, Length 1100, Resolution: 600 dpi
Document Type
: Black and White
"Scan Settings"
Output
: Bilevel
The following dialog box appears, together with the scanned image.
Measures the distance,
based on the scanned image
When actual and theoretical values appear
in their respective boxes, you can click the
Calculate button to calculate the feed.
The calculated feed will appear in this box.
Click this button to specify
the correction value for the scanner.
Click this button to display
the value stored in the scanner.
Click this button to
display the default value.
Type in the measured
distance here.
(5) Type the distance between a and c measured with a glass scale in the "Actual" box.
(6) Click anywhere within the "Theoretical" box and use the crosshairs cursor to click the white corner
indicated by arrow "a" on the scanned image.