CS610-UM-251-9370
8-31
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
Adjusting the high position elevator sensor
(1) After adjusting the low position elevator sensor, press the FORWARD button until the slider goes up.
(2) Confi rm the gap between the 4-mm holes in the slider and the side panel.
(3) Adjust the gap using the FORWARD button and the REVERSE button.
(4) Install the sensor at the position where the slider goes up. The sensor should be on at this position.
M2L10 binding head screw
High position elevator sensor
4 mm hole
Slider
The gap between the 4-mm holes in the slider and the side panel
To be within 2 mm.
Side Panel
Содержание CS610-11eN