Troubleshooting
Troubleshooting
Troubleshooting
Installing and servicing this equipment requires access to parts which may cause an electric shock or
other serious injury if the work is not performed properly. Do not install or repair this equipment unless
you are trained and qualified.
Follow the
Fluid Voltage Discharge and Grounding Procedure, page 29
, before checking or servicing the
system and whenever you are instructed to discharge the voltage.
To reduce the risk of injection injury, follow the
Pressure Relief Procedure, page 30
, whenever you are
instructed to relieve the pressure.
1.
Follow the
Pressure Relief Procedure, page
before checking or repairing the system.
2.
Check all possible problems and causes before
disassembling the system.
General
General
General Troubleshooting
Troubleshooting
Troubleshooting
Problem
Problem
Problem
Diagnosis
Diagnosis
Diagnosis
Solution
Solution
Solution
Prime
Incorrect mode.
1.
Change to Prime mode.
2.
Trigger the gun.
3.
Turn on the fluid supply and
check the incoming fluid
pressure.
Inlet valve is off or stuck.
Test the inlet valve using Main-
tenance screen 5 as described
in
Service the solenoid valve or fluid
valve. See
The isolation fluid pump is not
calibrated and is not showing as
being empty.
Calibrate the pump and try
Prime mode again. See
The fluid pressure supplied to the
system is too low.
Increase the supply fluid pressure.
Maximum is 100 psi (0.7 MPa, 7.0
bar).
The system does not prime.
The fluid pressure to the gun is set
to zero or very low.
Adjust the gun fluid pressure
setting.
Fluid leaks appear.
Seals are worn or there are loose
connections.
See
Check for Fluid Leaks, page 68
to
locate and correct.
3A8492A
71