Color
Color
Color Change
Change
Change Module
Module
Module Configuration
Configuration
Configuration
Configure each module according to its designated
number, as follows:
NOTICE
NOTICE
NOTICE
To avoid damaging the circuit boards, wear Part
No. 112190 grounding strap on your wrist and
ground appropriately.
To avoid electrical component damage, remove all
system power before plugging any connectors.
1.
Prepare the electrical controls for service. Follow
the steps in
Prepare the Electrical Controls for
.
2.
Disconnect electrical power from the system.
3.
Open the color change module. Locate switches
S4, S5, and S6 on the control module board. The
switches are shipped in the OFF position.
4.
For each module, set the switches to ON or OFF,
as shown in the following table.
Non
Non
Non---IS
IS
IS Control
Control
Control Module
Module
Module Switch
Switch
Switch Settings
Settings
Settings
Control
Control
Control
Module
Module
Module
S6
S6
S6
S5
S5
S5
S4
S4
S4
Electronic
Controls
OFF
ON
OFF
ON
OFF
ON
Color
Change
OFF
ON
OFF
ON
OFF
ON
Replace
Replace
Replace the
the
the Color
Color
Color Change
Change
Change Board
Board
Board
NOTICE
NOTICE
NOTICE
To avoid damaging the circuit boards, wear Part
No. 112190 grounding strap on your wrist and
ground appropriately.
To avoid electrical component damage, remove all
system power before plugging any connectors.
1.
Prepare the electrical controls for service. Follow
the steps in
Prepare the Electrical Controls for
.
2.
Disconnect electrical power from the system.
3.
Remove the color change module cover (704).
4.
Note where each cable is connected, then
disconnect all cables from the color change
board connectors.
5.
Remove the seven mounting screws (703) and
the board (702).
6.
Install the new board. Reinstall the screws.
7.
Reconnect the cables to the proper connectors,
as noted in step 3.
8.
Reinstall the cover (704). Restore electrical
power to the system.
130
3A8492A
Содержание HydroShield WABH00