Remove
Remove
Remove the
the
the Isolation
Isolation
Isolation Valve
Valve
Valve Stem
Stem
Stem
This procedure requires the sleeve tool (112) and
stem tool (113). See
.
1.
Prepare the isolation system for service. See
Prepare the Isolation System for Service, page
90
2.
Remove the isolation valve from the cabinet. See
Remove the Isolation Valve from the Cabinet,
page 91
.
3.
Place the sleeve tool (112) over the isolation
valve sleeve (221) and screw onto the housing
(218).
4.
Thread the stem tool (113) into the sleeve tool
(112) and tighten to interlock.
5.
Rotate both tools (112, 113) as one to apply
pressure to the spring (220) inside. When both
tools are tightened, the valve is opened, allowing
the valve stem (222) to come out.
6.
Insert a 3/16 inch Allen wrench into the end of
the valve stem (222) and turn with moderate
force to start.
7.
Unscrew until the valve stem (222) can be pulled
out.
Note
Be careful not to scratch the valve stem
(222) when extracting and handling.
8.
Unscrew both tools (112, 113) together until they
loosen the spring (220) and come off.
9.
Unscrew the stem tool (113) from the sleeve
tool (112) and remove the isolation valve sleeve
(221) and spring (220).
10. Replace the valve stem o-rings. See
Isolation Valve Stem O-rings, page 96
Figure 36 Tools Removing Valve Stem
Replace
Replace
Replace the
the
the Isolation
Isolation
Isolation Valve
Valve
Valve Stem
Stem
Stem O
O
O---rings
rings
rings
Use this procedure to replace the three o-rings (219,
2 x 228) on the isolation valve stem (222). Replacing
these o-rings may be necessary if the isolation valve
begins to leak.
1.
Remove the three o-rings (219, 2 x 228).
Note
Do not pry the o-rings off of the valve
stem. You may need to pinch the o-ring
to form a loop and then pull it off. You
may also cut each o-ring to remove.
2.
Replace the o-rings:
a.
Roll o-ring (219) over the valve stem (222)
threads until it fits into the groove.
b.
Roll one o-ring (228) over the valve stem
(222) threads until it fits into the groove.
c.
From the other end of the valve stem (222),
roll the second o-ring (228) onto the shaft
until it fits into the groove.
d.
Grease all 3 o-rings.
Figure 37 Replacing the Isolation Valve
O-rings
3.
Inspect the o-ring (219) inside the shuttle housing
(218) to make sure that it is still in place. Remove
and replace if needed.
96
3A8492A
Содержание HydroShield WABH00
Страница 139: ...Notes Notes Notes Notes 3A8492A 139...