9 Calibration
Calibration
Calibration Events
Events
Events
Code
Code
Code
Type
Type
Type
Name
Name
Name
Description
Description
Description
Solution
Solution
Solution
ENA1
Advisory
Linear Sensor Full
Calibrated
System successfully
calibrated Linear
Sensor full reading.
Not applicable.
ENA2
Advisory
Linear Sensor Empty
Calibrated
System successfully
calibrated Linear
Sensor empty
reading.
Not applicable.
P511
Alarm
V/P Cal Failed Air
V/P calibration failed
for the Air V/P
• Check V2P connections.
• Verify V2P operation
• Contact Graco technical support.
P513
Alarm
V/P Cal Failed Fluid
V/P Calibration failed
for the Fluid V/P
• Check V2P connections.
• Verify V2P operation
• Contact Graco technical support.
EN11
Advisory
V/P Cal Air
Air V/P Calibration
successful
Not applicable.
EN13
Advisory
V/P Cal Fluid
Fluid V/P Calibration
successful
Not applicable.