Code
Code
Code
Type
Type
Type
Name
Name
Name
Description
Description
Description
Solution
Solution
Solution
N611
Alarm
Isolation Valve
Timeout
Isolation valve was
not detected in the
expected position.
• Verify that the isola-
tion valve moves using
Maintenance 3: Shuttle Valve
Resets and Test, page 60
• Verify that the top
sensor is detected using
• Verify that the bottom
sensor is detected using
• Verify that the sensors are
connected.
N612
Alarm
Shuttle Top Timeout
Isolation valve was
not detected in the
expected position.
• Verify that the isolation valve
moves using the Maintenance
screen.
• Verify that the top sensor is
detected using the Status screen.
• Verify that the bottom sensor is
detected using the Status screen.
• Verify that the sensors are
connected.
F7P0
Alarm
Invalid Air Flow
Gun airflow is
detected when it
should be off.
• Determine if there is an air leak in
the system.
• Check the air flow switch.
• Check Air V/P.
• Contact Graco technical support.
SGD1
Alarm
Gun Flush Box Open
The gun flush box was
left open when the
system was trying to
attempt a purge.
Close the gun flush box.