Problem
Problem
Problem
Diagnosis
Diagnosis
Diagnosis
Solution
Solution
Solution
The system does not spray.
1.
The system is not in Spray
mode.
2.
The isolation fluid pump is
empty and there is no material
to spray.
3.
The fluid pressure is too low
or zero.
4.
The paint trigger signal is not
being recognized.
1.
Change to Spray mode.
2.
Give the system time to fill
before trying to paint.
3.
Increase the gun fluid pressure
on the Home screen or Preset
screen.
4.
Be sure the paint trigger input
is getting at least 70 psi. If
this does not correct the issue,
check the pressure switch
and wiring in the electronics
control panel.
Note
Check the Status screen to
see if the system detects
the gun trigger. See
Air is in the fluid.
Entering Spray mode before the
system is primed.
Enter Spray mode after priming
the system.
Improper spray pattern or gun
operation problem.
Issue with spray gun setup or
maintenance.
Refer to your gun manual.
System is in Standby mode.
Change to Prime, Purge, or Spray
mode.
No fluid when gun is triggered (or
wrong fluid pressure).
Issue with the regulator that sends
air to drive the high pressure pump
(75).
• Set the gun fluid pressure on the
Home screen or Preset screen.
• Check the electro/pneumatic
regulator (V2P) (415)
function using Maintenance
screen 9.
See
.
Low spraying voltage.
Increase the air pressure or the
voltage setting for the gun.
Poor wrap.
Issue with spray gun setup or
maintenance.
Refer to your gun manual.
• The ground rod (18) is not
raising.
• The isolation valve (227) is not
raising.
• The components or cabinet (9)
is dirty.
• The electrostatic shields (12 and
82) are not in place.
See
The ES request input does not
recognize a signal and does not
raise the ground rod.
Use the Status screen to see
whether the system detects
the ES request input. See
and
Low or no spraying voltage.
3A8492A