5.2 Pin Assignment
The magnet sensor has two electrical connectors. The 8 pin connector ST 2 carries all sig-
nals that are necessary for operating the sensor. The 5 pin connector ST 1 is used for con-
figuration, diagnosis and software updates. This connector should be accessible or extende
to an accessible place (for possible connection cables see section 3.2.3 on page 13). Both
connectors can alternatively be used to supply power to the sensor. The pins for supply volt-
age and supply GND are plated-through, thus if both connectors are to be connected to sup-
ply voltage at once the supply voltage has to come from the same source.
Figure 12
Positions of the connectors
5.2.1 ST 1 Service / Configuration
5 pin M 12 panel connector (A coded)
5.2.2 ST 2 Operation
8 pin M 12 panel connector (A coded)
ST 1
Pin
Signal
Annotation
1
+Ub (24V)
supply voltage
(plated-through to ST 2 Pin 1)
2
—
n.c.
3
TxD
RS232 data output
4
RxD
RS232 data input
5
GND
supply GND
(plated-through to ST 2 Pin 5)
Table 6
Pin assignment ST 1 5 pin
ST 2
Pin
Signal
Annotation
1
+Ub (24V)
supply voltage
2
GND
supply GND
3
DIN 1
digital inputs: Turnoff selection,
4
DIN 2
5
AOUT 1 (X) *)
analog outputs:
Outputs track guidance
6
AOUT 2 (Z) *)
7
DOUT1 (max. 20mA)
digital Detect output: Output track
deUb (24V)
8
n.c.
*) Voltage range configurable (see section 6.4.2 on page 26)
Table 7
Pin assignment ST 2 8 pin
M12 x 1 circular connector
8 pin (male)
M12 x 1 circular connector
5 pin (male)