Preliminary Device Description HG G-19600ZA | English, Revision 02 | Date: 13.03.2018
29
Software – Chapter 6
6.4.5 (4) RAW data monitor
In this menu raw data of the sub systems is shown. Additionally the value
sum of flux
density
is shown. This is needed for the commissioning.
Note
The magnet sensor determines a position with X, Y and Z coordinates. For the track guid-
ance only X and Z are used and output. In the RAW data monitor the internal value for Y is
also shown.
Figure 22
Menu RAW data monitor
Note
If the compensation for a static magnetic field is activated the raw data shown in this menu
is already calculated with the compensation included (see section 4.2 on page 16).
HG 19600 Serialnumber: 999999 Firmwareversion: V0.45
RAW data monitor
__ __
| | | |
---------------------------------
| HG 19600 O O O O X |
| |
---------------------------------
system 3 system 2 system 1
X -0.015 [mT] 0.011 [mT] 0.028 [mT]
Y -0.068 [mT] -0.041 [mT] -0.060 [mT]
Z 0.067 [mT] 0.066 [mT] 0.040 [mT]
track No No No
detect
sum of flux density: 0.231
(ESC) QUIT
Status: DIN:00 DOUT:0 AOUT1(X): 0.0V AOUT2(Z): 0.0V