![Gotting HG G-19600ZA Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/gotting/hg-g-19600za/hg-g-19600za_manual_2247527032.webp)
Preliminary Device Description HG G-19600ZA | English, Revision 02 | Date: 13.03.2018
32
Chapter 8 – Technical Data
8
Technical Data
Technical Data Magnet Sensor
Nominal reading height
60 mm
when using the magnetic tape
HW MAT00003, see Table 1 on page 10. For
different magnetic tape a different reading
height might be needed.
Casing dimensions
156 x 31 x 53 mm (W x D x H)
Casing material
Polycarbonate
Weight
150 g
Protection class
IP 54
Relative humidity at 25° C
95% (without condensation)
Operating temperature range
-20° C to +50° C
Storage temperature range
-20° C to +70° C
Supply voltage
+ 24VDC
Current consumption
< 100 mA
Connector
2 Stecker M12 (1x 5 pol. / 1x 8 pol.)
Analog outputs
– AOUT 1 (X): -10 to +10 VDC
– AOUT 2 (Z): 0-10 VDC
Digital output
Detect: +24 VDC (+Ub), max. 20 mA
Serial interface
RS 232
Table 12
Technical Data