Preliminary Device Description HG G-19600ZA | English, Revision 02 | Date: 13.03.2018
19
Hardware – Chapter 5
5
Hardware
5.1 LEDs
There are 5 LEDs to control the sensor‘s function.
Figure 11
Positions of the LEDs
LED
Meaning
PWR
blinks during normal operation
ERR
blinks if errors occur; error codes see Table 5 below
TR 1
Threshold left system exceeded
TR 2
Threshold center system exceeded
TR 3
Threshold right system exceeded
Table 4
Meaning of the LEDs
TR3 TR2 TR1
Error
code *)
Error description
Possible correction
off
off
on
0x01
– sensor overloaded
– magnetic field too
strong
– remove magnetic interference
source
– sensor mounted too low
off
on
off
0x02
System error
Please contact the Götting service
department
on
off
off
0x04
*) Errors can occur simultaneously, then the error codes in the output of the service pro-
gram are summed up.
Table 5
Output of error codes via the LEDs / possible correction