46
Gossen Metrawatt GmbH
4.13
Triggered Operation
When the triggering mode is EXTernal, the triggered operations are shown below:
1
Set pending trigger function (see section 2.8).
2
Press the
key +
key or trigger terminal (TRIG IN) to receive TTL falling edge, and a trigger occurs.
Example 1:
Select “List” for the trigger function to trigger a sequence operation. The sequence is the one mentioned in Example 1 in
The detailed operations are shown below:
For the above operating procedures, the corresponding SCPI commands should be:
TRIG:FUNC LIST
Selects „LIST“ for trigger function
TRIG
A trigger occurs
4.14
Main Menu
The operating procedures for the main menu are shown below:
1
Press the
key to enter into the main menu.
2
Use
▲
and
▼
keys to select the menu item.
3
Use the knob or
◄
►
keys to select the parameter; or use Entry keys or the knob together with
◄
►
keys to input set value.
Press
key to exit the parameter modification or exit the main menu.
4
Press the
Enter
key to confirm.
5
Press the
key to exit the main menu.
4.14.1 Loading Default Values
Example:
Load the default values.
The detailed operations are shown below:
Steps
Description
Step 1
Select “List” in main menu for the trigger function (please see section 4.14.6 for detailed introduction).
Step 2
Press
key +
key or trigger terminal (TRIG IN) to receive TTL low level. The load‘s input will change accordingly when
the sequence parameters are changed. Pressing
key +
key has the same effect as pressing
key +
key
at this time.
Procedure
Description
Display
1
Press the
key to enter into the main menu.
Load Default
:
Yes *No
2
Use the knob or
◄
key to select the parameter “Yes”. Press the
Enter
key to confirm.
Load Default
:
*Yes No
3
Press the
key to exit the main menu.