For the above operating procedures, the corresponding SCPI commands should be:
MODE
CCH
Sets the mode
TRAN
ON
Enables the transient operation
CURR:LOW
1
Sets a value to low level
CURR:HIGH
5
Sets a value to high level
TRAN:HTIME
200ms
Sets a value to high level time
TRAN:RTIME
10us
Sets a value to time for rising edge
TRAN:FTIME
10us
Sets a value to time for falling edge
TRAN:MODE
PULS
Selects pulsed transient operation
INPUT
ON
Turns on the load
.
.
Trig One
trigger
occurs
4.7.3
Toggled Transient Operation
Example 1:
Assume that the load is in external triggering mode, set the load resistance value to periodically switch between 200
Ω
and
500
Ω
; set the time for rising edge (TimeR) to 10 ms; set time for falling edge (TimeF) to 10 ms; the load is in toggled transient opera-
tion, and a trigger occurs at this time.
For the above operating procedures, the corresponding SCPI commands should be:
MODE
CRH
Sets the mode
TRAN
ON
Enables the transient operation
RES:LLEV
200
Sets a value to low level
RES:HLEV
500
Sets a value to high level
TRAN:RTIME
10us
Sets a value to time for rising edge
TRAN:FTIME
10us
Sets a value to time for falling edge
TRAN:MODE
TOGG
Selects toggled operation
INPUT
ON
Turns on the load
.
.
Trig
One trigger occurs
Procedure
Description
Display
1
Press the
key to enter into the mode selection and parameter setting menu; use the
▲ ▼
keys to select CRH
mode; press the
Enter
key to confirm and exit the mode selection and parameter setting menu.
0.000V
0.000A
20.000
Ω
CRH
OFF
2
Press the
Tran
key to enter into transient operation. The display shows “t” to indicate in CRH status.
0.000V
0.000A
2000.0
Ω
tCRH OFF
3
Press the
key to enter into the transient operation menu.
►
LevelL:
2000.0
Ω
LevelH:
2000.0
Ω
4
Use Entry keys or use the knob together with
◄
►
keys to set LevelL to 200, and press the
Enter
key to confirm.
LevelL: 200.00
Ω
►
LevelH: 2000.0
Ω
5
Use the Entry keys or the knob together with
◄
►
keys to set LevelH to 500, and press
Enter
key to confirm.
►
TimeL: 400.00ms
TimeH: 200.00ms
6
Press the
▼
key to select TimeR; Use the Entry keys or the knob together with
◄
►
keys to set TimeR to 10 ms, and
press the
Enter
key to confirm.
TimeR:
10.00ms
►
TimeF: 10.00ms
7
Use the Entry keys or the knob together with
◄
►
keys to set TimeF to 10 ms, and press
Enter
key to confirm.
►
Mode:
◄
Puls
►
8
Use
◄
►
keys or knob to set Mode value to Togg, and press the
Enter
key to confirm.
►
Mode:
◄
Togg
►
9
Press the
key to exit the transient operation menu.
0.000V
0.000A
200.00
Ω
tCRH
OFF
10
Press the
key to turn on the load.
0.000V
0.000A
200.00
Ω
tCRH
11
One trigger occurs when pressing
+
key or the signal at the trigger input terminal (TRIG IN) is low level.
0.000V
0.000A
500.00
Ω
tCRH ON