Connecting multiple fixtures to power in a chain
You can connect fixtures to power in a daisy-chain to simplify your power circuit
layout.
Warning!
The power input cable supplied with the fixture is rated 16 A
maximum. Add together the maximum current draw ratings of all the
devices that you intend to connect to power in a daisy chain and do not
create a chain with a total maximum current draw of more than 16 A, or
you will create a risk of fire and electric shock. Respect the following safety limits:
●
Do not connect more than
six (6) FP7 fixtures
to power in a chain at
100-120 V,
60 Hz
.
●
Do not connect more than
twelve (12) FP7 fixtures
to power in a chain at
200-240 V,
50 Hz
.
To connect fixtures to power in a chain:
Obtain power relay cables that have male and female IP65-rated Neutrik
powerCON connectors. Cables must be minimum 14 AWG or 1.5mm2, rated
minimum 16 A and suitable for the environment and application.
Check that the total current draw of all the devices in the chain will not exceed
16 A.
Check that power is not applied to the input cable.
Connect the power input cable to the MAINS IN socket (see
Figure 2 on page 11)
following the instructions given in the previous section.
Connect a relay cable to the
MAINS OUT
socket (see
Figure 2 on page 11) of the
first fixture and to the
MAINS IN
socket of the next fixture in the chain. Continue until
the chain is complete.
Do not expose cable connectors to bending forces, by letting cable hang from a
connector for example, as this may affect its ingress protection and allow water to
enter the connection.
Before applying power, check that that nobody is looking directly into the front of a
fixture.
Connecting to a power circuit
If using the fixture outdoors, make sure that all cable connections are protected from
water and moisture.
It is possible to install a cord cap / mains power plug that is suitable for your local
convenience receptacles / power sockets on the supplied power input cable. If you
do this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a
connection to ground / earth and that it has an integral cable grip. Follow the cord
cap / plug manufacturer’s assembly instructions.
If you need to install a Neutrik powerCON connector on a power cable, follow the
instructions given in the Support area of the Neutrik website at www.neutrik.com.