www.glp.de
22
Fusion Par FP7 User Manual Rev. A
IR Prio
If enabled, signals from the infrared remote that is available from GLP as an accessory
take priority over any DMX signals that the fixture is receiving.
Boot
Determines what the fixture does when power is applied:
●
Auto
sets the fixture to resume the action that it was performing when power was
shut down. If the fixture was operating under DMX control, it will wait for a DMX
signal again.
●
DMX
sets the fixture to enter DMX control operation when power is applied. It will not
give any light output until it receives a DMX signal.
●
Static
sets the fixture to show the static scene programmed in the
St-Alone
Static
menu (see later in this section) when power is applied.
If the fixture begins to receive a DMX signal while showing the static scene, DMX
commands will take priority by default. If you want the Static scene to take priority,
set
Boot
DMX Hi P
to
Off
.
●
Program
sets the fixture to run the dynamic sequence
P1
,
P2
or
P3
programmed in
the
St-Alone
P Edit
menu (see later in this section) when power is applied.
If the fixture begins to receive a DMX signal while running
P1
,
P2
or
P3
, DMX
commands will take priority by default. If you want
P1
,
P2
or
P3
to take priority, set
Boot
DMX Hi P
to
Off
.
St-Alone
The St-Alone menu gives a range of options for setting the fixture’s autonomous stand-
alone behavior.
Test
Runs a factory-programmed sequence that tests all colors and all LEDs.
Master
Lets you configure the fixture’s master-slave functionality during stand-alone operation:
●
Alone
sets the fixture to act independently. It will not act as a master or as a slave
fixture.
●
Master
sets the fixture to act as the master fixture in a master-slave setup. It will run
the static scene or programmed sequence (
P1
,
P2
or
P3
) that it is set to. It will also
send out all three programmed sequences (
P1
,
P2
and
P3
) over the DMX data link.
●
The
Slave
settings
Slave 1
,
Slave 2
and
Slave 3
set the fixture to act as a slave fixture
in a master-slave setup:
-
A fixture set to
Slave 1
will run the programmed sequence
P1
that is being sent by
the Master fixture.
-
A fixture set to
Slave 2
will run the programmed sequence
P2
that is being sent by
the Master fixture.