Use only Neutrik powerCON TRUE1 IP65-rated connectors to make power
connections to the fixture.
●
Line up the keys and keyways in Neutrik powerCON TRUE1 power connectors
carefully before inserting a cable connector. If a cable connector is difficult to insert
or twist, do not force it. Instead, remove it and check to make sure that keys and
keyways are lined up correctly.
●
Use only IP65-rated XLR connectors to make data connections to the fixture.
●
Keep the rubber connector seals correctly installed on all unused connectors at all
times.
●
Do not expose the cable connectors to bending forces (by allowing the weight of
cables to hang from connectors, for example) as this may affect their ingress
protection and allow water to enter the connections.
●
Disconnect the product from power immediately if the power plug or any seal,
cover, cable, or other component is damaged, defective, deformed, wet or
showing signs of overheating. Do not reapply power until the product has been
repaired and made safe by a technician authorized by GLP.
●
Before using the product, check that all power distribution equipment and cables
are in perfect condition and rated for the electrical requirements of all connected
devices.
●
Use minimum 14 AWG or 1.5 mm
2
power input and relay cables that are minimum
16 A rated and temperature-rated to suit the application. In the USA and Canada
the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be
type H05VV-F or equivalent.
●
Do not connect devices to power in a chain using their power throughput
connectors if the total maximum current draw of all the devices in the chain when
added together will exceed the current rating of any cable or connector used at
any point in the chain. The supplied power input cable is rated as follows:
-
US power cable: 16 A, 14 AWG, UL listed, E304117, SJT, 4.9 ft.
-
EU power cable: 16 A, 1.5 mm², H05VV-F, 1.5 m
Do not connect more than six (6) FP7 fixtures to power in a chain at 100-120 V, 60 Hz.
Do not connect more than twelve (12) FP7 fixtures to power in a chain at 200-240 V,
50 Hz.
●
The voltage and frequency at the MAINS THRU socket are the same as the voltage
and frequency applied to the MAINS IN socket. Only connect devices to the MAINS
THRU socket that accept this voltage and frequency.
●
If you suspect that a fuse has blown, disconnect the product from power and send
it to a technician authorized by GLP for repair.
Fire safety and protection from burns
●
Do not operate the product if the ambient temperature (Ta) exceeds 45° C (115° F).