Global JUNIOR V4-L Скачать руководство пользователя страница 3

Sounder Audibility Check...................................................................................................................................................

Panel................................................................................................................................................................................

Analogue Loop Monitoring..............................................................................................................................................

Open Circuit Test.........................................................................................................................................................

Conventional Sounder Monitoring................................................................................................................................
Detector Tests........................................................................................................................................................................

Detector Tests By Zone..............................................................................................................................................
Unassigned Detector Test........................................................................................................................................

Wrapping Up Installation And Commissioning........................................................................................................ 

Battery Fault Message Test......................................................................................................................................
Power  Failure Test.......................................................................................................................................................

Programming Functions General...................................................................................................................................

Complete List Of Functions.....................................................................................................................................
Keys To Use Within Functions.................................................................................................................................
General............................................................................................................................................................................

1 Review Historic Log

.......................................................................................................................................................

 

1-1 Display Historic Log.....................................................................................................................................................
1-3 Clear Historic Log..........................................................................................................................................................
1-5 Read/Clear Autostart Count......................................................................................................................................

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Zones - Disable & Assign

............................................................................................................................................

3-1 Disable Zones.................................................................................................................................................................
3-2 Assign Sounder Groups to Zones...........................................................................................................................
3-3 Assign I/O Groups to Zones......................................................................................................................................
3-4 Assign Zone to Device................................................................................................................................................
3-5 Zone Sounder Delay Set-up......................................................................................................................................

 

                                                 

4 Sounders - Disable & Assign

....................................................................................................................................

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-1 Sounder Configuration...............................................................................................................................................
4-2 Configure Sounder Groups.......................................................................................................................................
4-3 Disable Sounders..........................................................................................................................................................
4-4 Assign Sounder Group to Device............................................................................................................................
4-5 Inhibit Sounders for Device......................................................................................................................................
4-6 Sounder Delay Set-up.................................................................................................................................................
4-7 Override Sounder Delays...........................................................................................................................................

ADVANCED FUNCTIONALITY

SPECIFIC FUNCTIONS

35
35
36
36
36
37
37
37
37
38
38

39
39
40
40

41

41
41
41

42

42
42
42
42
42

43

43
43
44
44
44
45
45

Manufacturers of Fire Detection Equipment

globalfire.pt

INSTALLATION & COMMISSIONING MANUAL - V1. 03/2015

JUNIOR V4-L

 - FIRE ALARM CONTROL PANEL

Содержание JUNIOR V4-L

Страница 1: ...of Fire Detection Equipment globalfire pt INSTALLATION COMMISSIONING MANUAL V1 03 2015 JUNIOR V4 L FIRE ALARM CONTROL PANEL INSTALLATION COMMISSIONING MANUAL VERSION 1 03 2015 JUNIOR V4 L FIRE ALARM...

Страница 2: ...MainBoard ConnectionDefinitions 19 FittingJuniorExpansionLoopCard 20 DataLoops 21 PanelRs485 22 RepeaterRs485 23 PanelFibreOptic 24 RepeaterFibreOptic 25 AnalogueLoop 26 ConventionalSounders 27 Auxili...

Страница 3: ...es Disable Assign 3 1 Disable Zones 3 2 Assign Sounder Groups to Zones 3 3 Assign I O Groups to Zones 3 4 Assign Zone to Device 3 5 Zone Sounder Delay Set up 4 Sounders Disable Assign 4 1 Sounder Conf...

Страница 4: ...Global Sensitivity Set up 6 1 9 Configure Timed Sensitivity 6 2 6 2 1 Select Device Heat Grade 6 2 2 Select Device Smoke Sensitivity 6 3 Discovery Specific 6 4 Automatic Address Setting SAM 6 4 1 Acti...

Страница 5: ...h Memory 8 3 2 Clear Non Volatile RAM 8 3 3 Calculate Customer Flash Checksum 8 3 4 Calculate Program Flash Checksum 8 4 Other Features 8 4 1 Active Installation Mode 8 4 2 Upload Download Link to PC...

Страница 6: ...32 individually programmable sounder addresses Full SAM MAM support Wizmart GFE protocol only 2 Fire output relays change over and 1 Fault relay nc opens on fault 2 conventional alarm outputs Individ...

Страница 7: ...BLE Pressingthisbuttonwillenable disableallsoundersbothconventionalsoundercircuitsandaddressablesounders DELAYSACTIVE Pressing this button will activate any preprogrammed delays The yellow LED associa...

Страница 8: ...ED ZONE LED CONNECTOR AUXILIARY POWER SUPPLY OUTPUT CLASS CHANGE OR REMOTE EVAC REMOTE DISABLEMENT OF SELECTED DETECTORS VOLTAGE FREE NORMALLY OPEN CONTACTS NON LATCHING ACTION PC Loader DB9 Female Co...

Страница 9: ...MODEL PS 65 27 EARTH POWER SUPPLY SPECIFICATION MEANWELL Model PS 65 27 MAINS SUPPLY VOLTAGE INTERNAL POWER SUPPLY TOTAL OUTPUT CURRENT SUPPLY AND BATTERY CHARGER MONITORED BATTERIES MONITORED MAX BA...

Страница 10: ...ng loop sounders and a 24 hour standby requirement Quiescent current in mA of the panel with everything connected Alarm current in Amps sounder load Standby time required in hours divided by 1000 Alar...

Страница 11: ...YSTEM FAULT SOUNDERS ACTIVATE SILENCE SYSTEM RESET LAMP TEST BUZZER SILENCE DELAYS ACTIVE SELECTED DETECTORS SOUNDERS DISABLE AUXILIARY RELAYS DISABLED TEST FAULT FIRE MANUFACTURED IN THE E U TO THE R...

Страница 12: ...IDENTIFYING COMPONENTS INSIDE JUNIOR Manufacturers of Fire Detection Equipment globalfire pt INSTALLATION COMMISSIONING MANUAL V1 03 2015 JUNIOR V4 L FIRE ALARM CONTROL PANEL...

Страница 13: ...OR MAIN BOARD Junior Expansion Loop Card Junior Expansion Loop Card REAR VIEW Manufacturers of Fire Detection Equipment globalfire pt INSTALLATION COMMISSIONING MANUAL V1 03 2015 JUNIOR V4 L FIRE ALAR...

Страница 14: ...UNICATION Typical cable form one end VIEW FROM TOP NOTE THROUGHOUT THE MANUAL THE PIN ON THE 5 WAY MOLEX INDICATES WHICH PIN IS RED N 1 VIEW FROM FRONT MALE FEMALE NOTE Junior can only be networked wi...

Страница 15: ...hestandardEN54pt 21997 AC 1999 thepanelsupportsancillary functionsthatarenotrequiredbytheabovementionedstandard namely AncillaryFunctions Panelnetworkconnectionports PaneltoPCprogrammingsoftware uploa...

Страница 16: ...oop between the panel and the repeater Alternatively it is possible to use multi mode dual core fibre optic cable or a TCP IPconnectionforthesamepurpose DataloopcableshouldbeRS422 485gradedatacable eg...

Страница 17: ...rsitedata Flash datastorageisveryrobustandneedsnopoweratalltoretainthedata LocalSounder Alocalconventionalsounderisanaudibleoutputdevice bellorsounder thatisconnectedtothe localbelloutputonthepanel Lo...

Страница 18: ...ding intothepowersupplyunit TheconnectorwithaBLUEwireleading intothepowersupplyunitistheNEUTRAL OtherPanelconnections These are detailed in the relevant following sections Most connections are made fr...

Страница 19: ...utton Auxiliary change over relay output 2 Activated by any fire present on the system disabled by front button Fault NC relay contact Activated by any fault present on the system opens on fault Remot...

Страница 20: ...efore the installation process of the card is initiated 3 After process is completed re apply power to the panel 4 Panel should be in installation mode Green Status LED should be flashing See function...

Страница 21: ...the case of RS422 485 and Fibre Optic this can be wired in the form of a Loop thus protecting the Data Loop from interruptions or short circuits by creating a bi directional communications flow If the...

Страница 22: ...B TX2 A TX2 B The interface inside the Junior panel must have the link jumpers OFF The interface inside the Mini Repeater must have the link jumpers ON PANEL REPEATER OFF ON J1 J2 LINKS JUNIOR PANEL C...

Страница 23: ...ter Then continue to connect OUT of one Repeater to IN of the next Repeater following the same connection rules as above When you reach the last Repeater in the loop make the connections as follows LO...

Страница 24: ...connections with the power turned off to avoid risk of permanent damage to the circuit boards The interface inside the Junior panel must have the link jumpers OFF The interface inside the Mini Repeat...

Страница 25: ...lly the same as for the Panel Panel Repeater NOTE Make all connections with the power turned off to avoid risk of permanent damage to the circuitboards Then continue to connect OUT of one Repeater to...

Страница 26: ...es the connection to all the analogue addressable devices and loop powered sounders Unless the loop is completed the panel will not be able to monitor its integrity open and short circuit monitoring C...

Страница 27: ...X1 and AUX2 Under the presence of any Fire Alarm condition these 2 relays will be energized Both set of contacts are of the change over type Max Contactcurrentratingforeachsetofrelaycontactsis1Amp 50V...

Страница 28: ...the primary supply should fail it also provides a charging output to maintainthebatteriesinafullychargedstate Before connecting the batteries check the voltage across the battery connection terminals...

Страница 29: ...and off Thepanelwillautomaticallydetectandmemorizeallthedevicesconnectedtotheloopinthesystem The default settings of the system mean that the unit will be ready to operate and detect a Fire incident f...

Страница 30: ...SOUNDERSDISABLE When this button is activated all sounders will be disabled and the LED will be lit Pressing it again will reenable the soundersandtheLEDwillturnoff SELECTEDDETECTORS Via the programm...

Страница 31: ...ds After that the screen will revert back to thefirstfault orfire TEST GeneralUserAccess nocodeentryrequired If the LED next to this button is illuminated then a test mode has been selected via the pr...

Страница 32: ...supply to the repeater is obtained directly from the auxiliary power supply output on the panel Applypowertotherepeater If the panel is powered up and the data loop connections between panel and repe...

Страница 33: ...t if code entry is not started within 10 seconds then the panel will revert back to it s default screen While entering the code you are allowed up to 5 seconds betweenkeypresses FunctionSelection The...

Страница 34: ...andclearthecustomerflash YoumustNOTdothisifyouhavebeensuppliedwithaSIMCARDpre programmedwithyoursitedata Selectfunction8 3 2ClearNon VolatileRAMandcleartheNVRAM ExitProgrammingmode PressSYSTEMRESET Wa...

Страница 35: ...2TestSounders Usingthisfunction allthesounders canbechecked ThePanelConventionalandLoopSounderswillsoundfor1secondthenbesilencedfor9seconds AnalogueLoopMonitoring Checkthatashortcircuitoropencircuiti...

Страница 36: ...EMRESET Enter programming mode and select function 7 3 Sounders on Test Activation This allows you to choose an audibleconfirmation that a device has detected a fire The audibleconfirmation consistsof...

Страница 37: ...em The basic minimum usually involves assigningtextlabelstothedeviceandZones Once you have completed this or if you have a pre programmed SIM CARD then do not forget to carry out the followingsteps Co...

Страница 38: ...setofbatteries Testonlytheactualbatteryconnections Remove the blue link from between the 2 batteries After a short delay the SUPPLY FAULT LED illuminates the panel buzzer sounds and the BatteryFault m...

Страница 39: ...panels programmed to use Apollo Discovery Protocol 6 3 1 Select Device Sensitivity Mode 6 3 2 Flashing Leds On Off 6 3 3 Disable Specific Flashing Leds 6 3 4 Re calibrate All Devices 6 3 5 Check for...

Страница 40: ...The cursor is often shown to highlight the item that is being changed Help Where possible help is displayed automatically NOTE If a fire occurs whilst the panel is in programming mode then programming...

Страница 41: ...ties of this panel will be a hands on approach aidedcloselybythismanual 1 Allthefunctionsassociatedwithreviewingorprintingeventsandsettings 1 1DisplayHistoricLog The panel logs all events in an intern...

Страница 42: ...fire is detected the 5th I O group is activated when a second fireisdetectedinthesameZone ThedetailsoftheactivationaresetupusingtheI Oprogrammingfunctions 3 4 Assign Zone to Device Allowsthedetection...

Страница 43: ...the Common Sounder Group P pulsing willoverride S silentand C willoverride P pulsing When a subsequent fire occurs the new Sounder Group information is added to the existing Sounder Groupinformation P...

Страница 44: ...heCommonSounderGroup 512 isnotactivatedwhenthedevicedetectsfire ZONAL TheZoneSounderGroupforthedeviceisnotactivatedwhenthedevicedetectsfire ALL Nosounders areactivatedwhenthedevicedetectsfire Inhibiti...

Страница 45: ...ed device willbequeuedfordelayedactivation ForsounderdelaystooperatethefrontpanelACTIVEDELAYSLEDhastobelit Thereisonlyonesounderdelaytimersowhenthisexpiresanyfurthersounderactivationswillbeimmediate I...

Страница 46: ...mulative 5 2SelectFaultI OGroup Allowsaspecified I Ogrouptobeactivatedifafaultcondition occurs Itisnotrecommended tousethesameI Ogroupforfireandfaultreporting 5 3AssignI OGrouptoDevice Allows an I O G...

Страница 47: ...a specific I O module to be set so that it activates immediately even if the rest of the I O is set to be activatedafteradelay AllowstheI O output delaytobeset ThisdelayappliestoallI Omoduleoutputs T...

Страница 48: ...d Disableddeviceshavebothinputsandoutputsdisabled Thisfunctiondoesnotdisablethe audible outputfromloopsounders Any devices that are disabled will also be indicated when programming mode is exited They...

Страница 49: ...ftheSounderConfigurationwassettoPRESETandalldelaysareignored Allows a detector to be set to override all zonal and global sounder and I O delay timers When this device is activated the Sounder Groups...

Страница 50: ...eandtimearesetcorrectly function8 1 1 Note thatin order to keep day nightand day settings consistenta day setting starts atsunrise which is set by function8 1 2 Thismeansthat forexample theSaturdayset...

Страница 51: ...sholdforsmokedetectorstobeset Eachindividualdetectorhasthefollowingsettings NORMAL LOW HIGH GLOBAL IfGLOBALisselectedthen dependingtheday theappropriate HIGH LOW NORMALorTIMEDsettingisused seefunction...

Страница 52: ...swhentheyarepolled Only Discovery devices that have had the flash disabled will not flash when polled see programming function 6 3 3 UsethisfunctiontoindividuallydisabletheLEDflashwhenpolledonDiscover...

Страница 53: ...tereadisdisplayedindecimal Readswillonlybeattemptedonsub panelsthataresetforDiscovery detectors IfthechosendeviceisnotaDiscovery deviceanerrorwillbereported thiserrorisnotlogged Allows a decimal value...

Страница 54: ...K d Verify the non existence of earth current leakage e Verify the cable lengths for the loop f Confirm the non existence of short or open circuits within the loop g Verify communications with standar...

Страница 55: ...e count will increase by one and by selecting the newly programmed address the device type address and analogue value can also be confirmed b Using function 7 3 the user can select to activate the sou...

Страница 56: ...ngASETmode Seefunction6 4 1 UsethisfunctiontoeraseasingleSAMonaspecificloop After all SAM s have been programmed in a loop perform a MASTER RESET to the panel followed by a confirmation using function...

Страница 57: ...st programmed address using function 6 4 3 andreprogramSAM IfthatdoesnotsolveproblemreplaceSAMmodule Rememberthataduplicateaddress faultwillonlyshowwithASETmodedisabled b SAMwithduplicateaddresses In...

Страница 58: ...oputintotestmode Exitprogrammingmode butDONOTpressSYSTEMRESETasthisclearsalltestmodes In test mode when a detector is activated the LED on the detector will be illuminated and the event will be report...

Страница 59: ...set for day and night function 6 1 9 then the times defined here are the timesthesensitivitychangewilltakeplace If delays have been set to be switched off at night function 8 1 3 then this will happen...

Страница 60: ...yspecificdetectorsthatwillstarttheEvacuateTimer TheEvacuateTimermustbeinDEVICEMODEtobeactivatedbyspecificdevices Seeprogrammingfunction8 1 4 Programming functions associated with the system response a...

Страница 61: ...under Group definitions will be cleared The Sounder Configuration will be set to PRESET All Zone text will be cleared All Zone Sounder and I O group settings will be cleared All Zone definitions will...

Страница 62: ...um will be re calculated as required Downloads of customer data also result in an automatic update of the checksum However if a SIM CARD is supplied with pre programmed data i e the data changed exter...

Страница 63: ...er removed replaced or added then Installation Mode must be selected so that the system can learnthenewconfiguration Ifyoudonotdothisthesystemwillreportafault Entering this function will automatically...

Страница 64: ...nsionRS232lead disconnectthepowertothepanel Connect the RS232 lead to the panel socket reapply power to the panel return to programming mode and go to function 8 4 2 do NOT press Enter yet Connect oth...

Страница 65: ...sum ThedefaultsettingforallprogrammingfunctionsisNONE Allowsthelanguagesettingtoforthesystemtobeset Dothiscarefully youwillneedtonavigatebacktothisfunctiontochangeitbackagain All text in the system wi...

Страница 66: ...cesperloop 125 Supports analogue addressable devices over a 2 wire combined power anddigitaldatatransmissionloop MaximumLoopcurrent 275mA Loopshortcircuit trip current 900mA Maximum recommended loop l...

Страница 67: ...tputs c 340mAforanaloguelooppower d 1Ampforbatterycharger AlarmCondition 800mAforconventionalsoundercircuits a b c DCOutputVoltage Maximum28 5VDC Minimum19 7VDC Max RippleVoltage 400mVpeak to peak Max...

Страница 68: ...orporates a set of rules for the design of all elements of the p s e and that its components have been selected for the intended purpose and expected to operate within their specification when the env...

Страница 69: ...Manufacturers of Fire Detection Equipment globalfire pt INSTALLATION COMMISSIONING MANUAL V1 03 2015 JUNIOR V4 L FIRE ALARM CONTROL PANEL...

Страница 70: ...Manufacturers of Fire Detection Equipment globalfire pt INSTALLATION COMMISSIONING MANUAL V1 03 2015 JUNIOR V4 L FIRE ALARM CONTROL PANEL...

Отзывы: