13
1. Push the stop buffers (1) into the existing grooves from the right and left and pre-
position them.
2.
Lightly
tighten the stop buffers with an Allen key (2).
3.13
Installing end piece
1. Connect the end piece to the runner with the earth connector (1).
For this purpose, align the earth connector so that one threaded rod is found in the
end piece and the other threaded rod is in the runner.
2. Tighten threaded rods.
3.14
Installing side panels
1. Insert a sliding block (2) for the side panel (1) and clamp with M6 x 12 threaded
rod.
2. Secure the side panel (1) to the end piece or to the runner with countersunk
tapping screw DIN 7982 M4.8 x 25 (3).
1
When tightening the threaded rods, the anodized layer of the end piece and
the runner must be pushed through.
1
2
1
3
The left side panel is always installed on the end piece.
The right side panel is installed directly to the runner.