17
3.19
Connecting transformer and controller
1. Strip three-lead cable (2), attach insulated wire-end ferrules and connect to
cable (1) at transformer (see terminal connection diagram).
2. Lay cable (2) to controller.
3. Shorten and strip cable (2) if necessary, attach insulated wire-end ferrules and
connect to cable terminals (3) of the controller.
3.20
Connecting geared motor and controller
Slimdrive SL
Slimdrive SL-FR 2M
Slimdrive SL
1. Lay rotary transducer cable (1) and motor connection cable (2) to controller.
2. Push the plug into the controller.
Slimdrive SL-FR 2M
1. Lay rotary transducer cable (1), motor connection cable (2) and motor
connection cable of the second SL-FR 2M (3) motor to the controller.
2. Push the plug into the controller.
2
1
2
3
Pay attention to the earth connection!
1
2
3
1
2