Before working on the electrical system:
•
disconnect the drive from the 230 V mains network and check to ensure that it is
not supplied with power.
•
disconnect the controller from the 24 V battery.
•
note that if an uninterruptible power supply (UPS) is used, the system will still be
supplied with power despite the fact that the power supply is disconnected.
Always use insulated wire-end ferrules for wire cores.
Attach safety labels to glass door leaves (Id. No. 081476).
Danger of injury by opened drive. Hair, clothing, cables etc. can be pulled in by
rotating parts!
Danger of injury by unprotected pinching, impact, shearing or drawing-in spots!
Danger of injury by broken glass!
Danger of injury by sharp edges in the drive!
Danger of injury during installation by freely moving parts!
Inspection of installed system
Measures for security and prevention of pinching, impact, shearing or drawing-in
spots:
•
Check the functioning of safety sensors and motion detectors.
•
The detection field of the motion detector in the exiting direction must cover the
opening width x 1.5 m in front of the door.
•
The motion detector in the exiting direction (see AutSchR) must detect people
moving faster than 0.1 m/s.
•
Check earth connection to all metal parts which can be touched.
Environmentally-conscious working
When disposing of the door system, separate the different materials and have them
recycled.
Do not dispose of batteries and storage cells with household waste.
Comply with the statutory regulations when disposing of the door system and the
batteries and storage cells.