9. Lay light barrier cables:
Pre-drill mounting profile into extension of sealing strips and lay cable in mounting
profile (see block diagram).
10. Lay cable of outside control sensor:
Pre-drill mounting profile in suitable position and pull in cables (see block
diagram).
11. Insert runner with pre-assembled modules into mounting profile.
12. Align runner laterally.
13. Brace runner over terminal strips with mounting profile so that the runner is
torsion-free:
– Push all 7 clamping strips between mounting profile and runner.
– Post/bolt lock design: position 5 inner terminal strips at height of inner posts
and position others between them.
– Wall and ceiling installation: position 5 inner terminal strips as required.
14. Brace left end piece:
– Check clamping of earth connector with runner.
– Connect above terminal strip with runner and mounting profile.
15. Insert cover (1) for runner and mounting profile.
Danger of injury!
Unsecured components may fall down when under load.
➮
Fully brace the runner.