16
3.17
Connecting alarm contact at locking device (optional)
1. Remove M2.3 x 10 bolts on indicator switch (1) of the locking device.
2. Place alarm contact switch (2) on the indicator switch (1).
3. Secure both switches to the locking device with M2.3 x 18 (3) bolts and lock
washers.
4. Connect cables.
5. Shorten actuator lever of alarm contact switch.
6. Check switching points of both switches. Bend actuator levers if necessary.
3.18
Installing cable holders and hood mounting brackets
1. Install hood mounting brackets (2) and fasten to a sliding block with an M6 x 16
Inbus-Ripp locking bolt.
Distribute hood mounting brackets evenly on the runner based on the prevailing
physical conditions.
2. Determine position of cable holders (1) and insert cable holders into the runner.
The cable holders are fastened by turning them 90° to the right.
3. Lay the cable in the cable holder and secure with cable ties.
1
2
3
Switches must switch shortly before the locking position is reached.
Switching is indicated by a clicking sound.
1
2
1
No cables may be located in the running area of the toothed belt, drivers and
roller carriages.