Gerber P2C™ 600
User's Manual
Operation
2-10
Press the
key to display the configuration menu. The different
configuration submenus can be accessed by pressing the
or
jogging key. A ll the values are displayed in metric regardless of the “MENU
UNITS” setting.
1. CUT
The CUT parameter determines the length that is cut with full pressure. Press the
or
jogging key to change the value. Press the
key to start the test
cut.
2. HALF
The HALF parameter determines the length that will be cut with reduced
pressure or without pressure. Press the
or
jogging key to change the
value. Press the
key to start the test cut.
3. PRES
The PRES parameter sets the pressure for “HALF”. Press the
or
jogging
key to change the value. Press the
key to start the test cut.
2.3.5. OVERCUT
The OVERCUT submenu enables you to generate an overcut in order to
facilitate weeding. Press the
or
jogging key to change the value.
The default value is 1.
The overcut setting can be disabled (=0) or set to any value between 0 (=off)
and 10. One unit is about 0.1 mm or 0.004 ".
The active overcut setting is marked with an asterisk (
!
) on the LCD.