Gerber P2C™ 600
User’s Manual
General Information
1-14
1.6. POWERING UP THE CUTTER
1.6.1. EARTHING (“GROUNDING”)
!
SAFETY WARNING
An insulated ground conductor must be installed as part of the branch
circuit that supplies power to the wall outlet to which the cutter is
connected. The ground conductor must have the same size, insulation
material and thickness as the grounded and ungrounded branch-
circuit supply conductors, but the insulating sheath should be green,
or green with yellow striping.
The ground conductor described above must be grounded at the
electrical distribution board, or, if power is supplied by a separate
system, at the power supply transformer/motor generator set.
The wall sockets into which the cutter is plugged must be of the
grounded type. The grounded conductors serving said wall sockets
must be properly connected to ground.
For emergency access the machine should be installed near to the
socket-outlet and easy accessible.
See Table 1-8 for the minimum and maximum operating voltage for the
different voltage ratings.
For information about operating voltage and the exact fuse ratings, see
Section 4.2.