NOTE
For setup and distortion measurements, set
output level to at least 30 dB above sensitivity
threshold (-80 dBm recommended).
3. Connect the analyzer’s RF I/O port to the
radio’s antenna connector.
4. Use the CURSOR ZONE keys to move the
cursor to the Audio Zone. Within the Audio
Zone, move the cursor to “Fixed 1 kHz:”
field. Select 1 kHz audio source as the
modulating signal (also available from the
MOD OUT connector on the front panel) by
turning 1 kHz on “~”. Set 1 kHz voltage level
to 0.4 volt.
5. Turn on the PROJ 25 CONV receiver and
tune receiver and analyzer to the same
frequency. Verify receiver locks onto test
signal.
6. Use the CURSOR ZONE keys on analyzer
front panel and move the cursor to the
Display Zone.
7. Place cursor in the “Display:” field and press
CLEAR SCOPE
screen should appear
similar to Figure 22-4.
8. Move the cursor to “Horiz:” field and press
200 us
softkey.
9. Move the cursor to “Vert:” field and press
200 mv
softkey.
10. Move the cursor to “Vert Position:” field.
Use
move up/move down
softkeys or rotary
control to position the modulating 1 kHz
waveform on a convenient graticule.
11. Move the cursor to “Horiz Position:” field.
Use move left/move right
softkeys or rotary
control to position the modulating 1 kHz
waveform on a convenient graticule.
12. Move the cursor to “Mrk:” field.
Press
V
softkey to display movable
markers that measure voltage
differential (Vp-p).
Press
T
softkey to display movable
markers that measure time differential
(sec).
Press
1/T
softkey to display movable
markers that measure reciprocal time.
13. Position the markers as desired using TUNING
knob (press
toggle marker
softkey to select
marker). The movable marker is indicated by a
red line. Observe digital readout of marked
values below “Mrk:” field.
288
Содержание R2600 Series
Страница 1: ...GENERAL DYNAMICS R2670 R2625 Series Communications System Analyzer OPERATOR S MANUAL CG 1089 Rev A...
Страница 2: ...CG 1089 Rev A R2670 R2625 Series Communications System Analyzer OPERATOR S MANUAL GENERAL DYNAMICS...
Страница 8: ...3 7 1 3 AC DC Voltmeter 41 3 7 1 4 INT DIST EXT DIST Meter 43 v...
Страница 46: ...This Page Intentionally Left Blank xxxvi...
Страница 66: ...DISPLAY ZONE RF ZONE AUDIO ZONE Figure 3 1 Screen Zone Arrangement 20...
Страница 68: ...Figure 3 2 System Help 22...
Страница 83: ...Figure 3 11 General Sequence Mode Select 37...
Страница 85: ...39 Figure 3 12 RF Display Zone...
Страница 88: ...Figure 3 14 Digital Voltmeter Screens 42...
Страница 102: ...Figure 3 22 Bar Graphs 56...
Страница 107: ...Figure 3 24 Memory Screens 61...
Страница 128: ...This Page Intentionally Left Blank 82...
Страница 202: ...This Page Intentionally Left Blank 156...
Страница 205: ...Figure 11 1 R 2670 with SECURENET Option Housing 159...
Страница 206: ...This Page Intentionally Left Blank 160...
Страница 218: ...Figure 13 8 Test Key Programming Display Figure 13 9 External Key Programming Display 172...
Страница 225: ...Figure 13 12 Duplex Mode Display Zone 179...
Страница 228: ...Figure 13 13 SECURENET Audio Zone Voice Generate Mode Figure 13 13 SECURENET Audio Zone Voice Generate Mode 182 182...
Страница 234: ...VOICE Figure 13 17 CLEAR SCOPE Markers 188...
Страница 236: ...This Page Intentionally Left Blank 190...
Страница 240: ...Figure 14 1 Radio BER Test Mode Audio Zone Figure 14 2 Radio BER Test Mode BER Meter Sample 194...
Страница 249: ...Figure 14 8 SECURENET CLEAR SCOPE Display of Output Modulation 203...
Страница 252: ...This Page Intentionally Left Blank 206...
Страница 255: ...1100 3 RS 232PORT KEYVARIABLE LOADER KVL PORT A S STRO OPTIONHOUSING Figure 15 1 ASTRO Option Housing 209...
Страница 256: ...210 This Page Intentionally Left Blank...
Страница 267: ...Figure 17 7 Encryption Select Display Figure 17 7 Encryption Select Display 221 221...
Страница 286: ...This Page Intentionally Left Blank 240...
Страница 291: ...Figure 18 1 Radio BER Test Mode Audio Zone Figure 18 2 Radio BER Test Mode BER Meter 245...
Страница 293: ...Figure 18 4 Receive BER 247...
Страница 298: ...Figure 18 6 ASTRO CLEAR SCOPE Display of Output Modulation 252...
Страница 304: ...Figure 21 1 PROJ 25 Version Screen Figure 21 2 PROJ 25 Options Screen 258...
Страница 309: ...Figure 21 6 SET UP Display Screen Figure 21 7 Encryption Select Display 263...
Страница 335: ...Figure 22 4 PROJ 25 CONV CLEAR SCOPE Display of Output Modulation 289...
Страница 339: ...Figure 24 1 PROJ 25 Version Screen Figure 24 2 PROJ 25 Options Screen 293...
Страница 354: ...Figure 25 3 Encryption Select Display Figure 25 4 Algorithm Select Display 308...
Страница 369: ...B 6 This Page Intentionally Left Blank...
Страница 379: ...This Page Intentionally Left Blank F 4...
Страница 383: ...This Page Intentionally Left Blank H 2...
Страница 389: ...J 4 This Page Intentionally Left Blank...
Страница 393: ...This Page Intentionally Left Blank K 4...
Страница 399: ...M 2 Table M 3 Registration Call Alert Dispatch Voice Error Messages Error Test Terminated by User Timeout Test Halted...
Страница 401: ...N 2 This Page Intentionally Left Blank...